Maintenance Instructions
Seite/Page 104 Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 6: Maintenance Instructions
26.1.11
6.7
Replace the air filter element
Fig. 6.7-1: Air suction housing
Pull the holder out to change the element.
Fig. 6.7-2: Air filter element
Open the air suction holder by loosen the two quick release
fasteners.
If no change of the cooling water level can be determined, the generator is started for 5 minutes. Afterwards repeat
the de-aeration two - three times.
It is meaningful to repeat the de-aeration procedure also after some days again to guarantee that in the system
remained bubbles are removed.