![Fischer Panda 4000s PMS FC Manual Download Page 51](http://html1.mh-extra.com/html/fischer-panda/4000s-pms-fc/4000s-pms-fc_manual_2294294051.webp)
The Panda Generator
26.1.11
Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 4: The Panda Generator Seite/Page 49
Fig. 4.4.3-4: Heat exchanger
Heat exchanger
The internal fresh water cooling circle is separated by the heat exchanger
from the raw water cooling circle. It is reached that the raw water circle does
not come with the construction units of the generator into contact. The raw
water commes from the oil cooler and is led at the discharge of the heat
exchanger directly into the exhaust elbow.
Fig. 4.4.3-5: Injection raw water
Injection port raw water
The point of introduction (point of injecting) for the raw water cooled exhaust
system of the marine generator is at the exhaust elbow. The exhaust elbow
must be checked regularly carefully for traces by corrosion.
Fig. 4.4.3-6: Raw water output
Raw water output
The raw water discharges together with the exhaust.