Maintenance Instructions
26.1.11
Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 6: Maintenance Instructions Seite/Page 107
Fig. 6.8.3-4: Impeller
Pull to the impeller with a multigrip pliers of the wave.
Fig. 6.8.3-5: Impeller
Check to the impeller for damage and replace it if necessary.
Before the reinsertion into the housing the impeller should have been lubricated with glycerin or with a non-mineral
oil based lubricant e.g. silicone spray.
Notice!:
Mark the impeller, to make sure that these is used in the correct
position at re-installation. This is very important, because the
impeller can dissolve otherwise very fast.
Fig. 6.8.3-6: Gasket
The impeller is attached to the pump wave if the old impeller is
used, pay attention to the before attached marking).
Fastening the cover and use a new gasket.
6.9
Conservation at longer operation interruption
6.9.1 Measures on preparation of the winter storage
1. Rinse raw water circuit with an anti-freeze solution, even if this contains a corrosion protection means. The raw
water inlet must be removed at the water cock. Over a hose connector the anti-freeze protection mixture is to be
sucked in from a container. The leaked cooling water with the exhaust is to be led back into the sucking in contai-