Remote Control Panel P4 Control
Seite 134 - Kapitel 9: Remote Control Panel P4 Control
P4_Control_eng.fm
Fischer Panda Datenblatt / Datasheet
Notice!:
Never switch off the battery until the generator has stopped.
5. If necessary, close sea cock.
:Notice!:
If the generator switches itself off with the operation with load
for temperature reasons, must be examined immediately,
which the cause is. That can be an error at the cooling system
or any error in the range of the outside cooling system.
9.4
Installation of the Panel
9.4.1 Connection of the remote control panel
Fig. 9.4.1-1: Remote control panel - back side
As standard a 7 core connection-cable, 7m long, is included in
the supply. Cores are numbered from 1 to 7. The control cables
are securely connected to the genset. On the back of the con-
trol panel there are terminals numbered from 1 - 7. Connect the
cores of the control-cable in respective order.
Please ensure that the remote control panel is installed in a
protected, dry and easily accessible place.
Ter..-Nro Terminator.-
name
i / o
Description
1
Vbat
i
Power supply 12V (+)
2
GND
i
Power supply 12V( -)
3
T-Cyl
i
Error „engine temp“. Temperature switch engine head in.
Can be setted up by jumper as NC or NO
Gives 22mA (12V +) on the switch.
This error is ignored while the „Start“ button is pressed and several seconds
after it is released (time set up by jumpers)
The yellow „Override“ LED is on while the error is ignored.
Status is displayed by green/red LED.