Fig. 5.3.5-1: Connection external ventilation valve
Cut the hose for the external vent valve...
Sample picture 4000s FC
Fig. 5.3.5-2:
.
Connection external ventilation valve
...and bent it upwards.
Both hose ends must be led out outside of the sound cover to
one point, if possible 600mm over the waterline in the midship
line. The valve is connected at the highest place with the two
hose ends.
sample picture
Notice!:
NOTE: The ventilation valve must be installed directly behind
the water pump.
If the water pump ceases, the valve spring ensures that air can enter and
therefore, a syphon effect is avoided.
Fig. 5.3.5-3: Ventilation valve
Ventilation valve