The Panda Generator
26.1.11
Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 4: The Panda Generator Seite/Page 61
4.4.7 Sensors and Switches for Operation Surveillance
Fig. 4.4.7-1: TThermo-switch at cylinder head
Thermo-switch at cylinder head
The thermo-switch at the cylinder head serves to monitor the generator tem-
perature.
Sample picture 4000s FC
Fig. 4.4.7-2: Thermo-switch at exhaust elbow
Thermo-switch at water-cooled exhaust elbow
This thermo switch is located at the water-cooled exhaust
elbow union and serves to monitor the temperature of the fresh
water cooling system. It takes a measurement at the hottest
spot, since the combustion gases are guided from the cylinder
head for the exhaust elbow.
Sample picture 4000s FC
Fig. 4.4.7-3: Thermo-switch coil
Thermo-switch in the generator coil
1. Generator coil
2. Thermo-switch
3. Housing
Two thermo switches are located inside the winding to protect the generator
coil, which for safety reasonsare installed independently in parallel.
Sample picture
1
3
2