![Fischer Panda 4000s PMS FC Manual Download Page 125](http://html1.mh-extra.com/html/fischer-panda/4000s-pms-fc/4000s-pms-fc_manual_2294294125.webp)
Tables
26.1.11
Panda_4000s_PMS_SCB_FCB_eng.R04 - Kapitel/Chapter 8: Tables Seite/Page 123
Generator overloaded by over-energizing.
Check that the proper capacitor type is installed and that
they are connected correctly.
Defective generator (windings, bearings, or other).
Generator must be sent to manufacturer for repair of
damaged bearings or winding.
Damaged engine.
Repair of bearing damage, etc., by Farymann-Service.
MOTOR RUNS IN OFF POSITION
Cause
Solution
Fuel inlet solenoid valve or throttle shut solenoid is not
switching off.
Check wire connections to solenoid. Check valve
functions as in the "Fuel Solenoid Valve" or in the trottle
shut off solenoid sections. Replace if necessary.
MOTOR STOPS BY ITSELF
Cause
Solution
Lack of fuel.
Check fuel supply system.
Excess heat in cooling system (thermo switch tripped)-
lack of cooling water. Is indicated on the remote control
panel.
Check cooling water system flow: water pump, inlet
water filter, extra heat exchanger coolant flow.
Lack of oil (oil pressure sensor tripped). Is indicated on
the remote control panel.
Check oil-level and if necessary top up.
Check motor's oil-pressure and have repaired by Fary-
mann-Service if necessary.
SOOTY, BLACK EXHAUST
Cause
Solution
Generator is overloaded.
Check electrical load and switch off unnecessary load.
Insufficient intake air.
Check intake air filter; clean if necessary.
Fuel injector faulty.
Replace injector.
Valve clearance incorrect.
Readjust valve clearance to correct value (refer to Fary-
mann-manual).
Poor fuel quality.
Use better quality diesel (recommended: 2-D Diesel).
Poor combustion.
Incorrect AFR (air/fuel ratio) due to motor timing adjust-
ment. Have motor serviced by Farymann.
GENERATOR MUST BE SHUT OFF IMMEDIATELY IF:
Cause
Solution
- motor rpm suddenly rises or drops
- unusual noise comes from genset
- exhaust colour suddenly becomes dark
- leakage in the cooling water system.
Refer to respective section of manual and if necessary,
have repaired by Farymann-Service, or Panda represen-
tative.
MOTOR SPEED DROPS