0DVWHU3URJUDPPLQJ/HYHO
3URJUDPPLQJ
068'31$
3.6.3.8 Zones Available
3UHVVLQJZKLOHYLHZLQJ=RQH6HWXS6FUHHQZLOOGLVSOD\DVFUHHQVLPLODUWRWKH
IROORZLQJ
7KHGLVSOD\ZLOOVKRZDOORIWKH]RQHVWKDWDUHVWLOODYDLODEOHIRUSURJUDPPLQJ1RWH
WKDWDQXSDQGRUGRZQDUURZPD\DSSHDULQWKHXSSHUULJKWFRUQHURIWKHGLVSOD\
LQGLFDWLQJWKDWDGGLWLRQDOVFUHHQVRI]RQHLQIRUPDWLRQH[LVWV3UHVVWKHXSRUGRZQ
DUURZNH\WRYLHZDGGLWLRQDOVFUHHQV
3.6.4 Loop Setup
Loop Setup allows the programmer to configure the SLC Loop for NFPA Style 4, 6 or 7
wiring and to select the loop protocol. Pressing
1
while viewing Programming Screen
#2 will cause the following screen to be displayed:
3.6.4.1 Style
7RSURJUDPWKH6/&6W\OHIRUWKHVHOHFWHGORRSSUHVV
IRU6W\OHZKLOHYLHZLQJ
/RRS6HWXS6FUHHQ,QWKHSUHFHGLQJH[DPSOHWKHFRQWUROSDQHOLVSURJUDPPHGIRU
6W\OH6/&ZLULQJDVLQGLFDWHGE\WKH
WRWKHULJKWRI
6W\OH
LQWKHGLVSOD\7R
FKDQJHWKHZLULQJVW\OHSUHVV
WRWRJJOHWKHGLVSOD\WRUHDG
6W\OH
(DFKSUHVVRI
WKH
NH\ZLOOFDXVHWKHGLVSOD\WRWRJJOHEHWZHHQ
6W\OH
DQG
6W\OH
Note that,
when programming the Loop Style, the programmer can only select between Style 4
and Style 6. To program a system for Style 7 wiring, the programmer must select the
Loop Setup for Style 6. Style 7 wiring is the same as Style 6 with the added
requirement that each addressable device on the loop must have a pair of isolator
modules, one on each side.
3.6.4.2 Loop Protocol
/RRS3URWRFROUHIHUVWRWKH6/&ORRSPRGHRIRSHUDWLRQ$WWKHSUHVHQWWLPHWKH
RQO\PRGHDYDLODEOHLV&/,3&ODVVLF/RRS,QWHUIDFH3URWRFROZKLFKLVXVHGIRUWKH
ROGHUOHJDF\DGGUHVVDEOHGHYLFHVVXFKDVWKH06HULHVPRGXOHVDQGGHWHFWRUV
1RWHWKDWWKHOHJDF\GHYLFHVFDQRSHUDWHRQO\LQ&/,3PRGHZKLOHWKHQHZHU
GHYLFHVDUHFRPSDWLEOHZLWK&/,3DQGDQ\IXWXUHPRGHVRIRSHUDWLRQ3UHVVLQJ
ZKLOHYLHZLQJWKH/RRS6HWXS6FUHHQZLOOKDYHQRHIIHFWRQSURJUDPPLQJDWWKLV
WLPH
'HYLFH$GGUHVVLQJ
,WLVLPSRUWDQWWRQRWHWKDWWKH068'DGGUHVVDEOHGHYLFHFDSDFLW\LV
GHWHFWRUVDQGFRQWUROPRQLWRUPRGXOHV1HZHUGHYLFHVFDQEHVHWWRDGGUHVVHV
KLJKHUWKDQEXWWKHVHDGGUHVVHVZLOOQRWIXQFWLRQZLWKWKH068'
1RWHWKDW,WLVSHUPLVVLEOHWRPL[ROGDQGQHZGHYLFHVRQWKHVDPHORRS
ZONE SETUP
1=ZONE TYPES
2=ZONES AVAILABLE
Zone Setup Screen #3
ZONES AVAILABLE
01 02 03 04 05 06 07
08 09 10 11 12 13 14
15 16 17 18 19 20 21
PROGRAMMING
1=LOOP SETUP
2=SYSTEM SETUP
3=VERIFY LOOP
Programming Screen #2
LOOP SETUP
1=STYLE 4
2=PROTOCOL CLIP
Loop Setup Screen