CONTROL DESCRIPTIONS
The appliance is equipped with the listed
control devices, required to run its main func-
tions.
A1)Main switch:
used to turn electrical pow-
er on and off.
A2)Button (RESET):
it is used to reset the
displayed parameters.
A3)Button (SETUP):
it is used to set the
work programs.
A4)Button:
to increase the value of the se-
lected parameter or to scroll the pro-
grammes.
A5)Button:
to decrease the value of the se-
lected parameter or to scroll the pro-
grammes.
A6)Button (NO/P):
used to display and set
the work programs.
A7)Button (YES):
it is used to confirm the values entered during programming.
A8)Display:
it shows warning/alarm messages and working parameters.
A9)Work program
A10)Programmed vacuum percentage
A11)Programmed inert gas percentage
A12)Work stage in progress
A13)Sealing time
A14)Sealing temperature.
A15)Signal indicating that the sealing plate heating stage is in progress
A16)Signal indicating that the sealing plate has reached the operating temperature
INSTRUCTIONS FOR USE
Language selection
1. Press and hold the button
(A3)
.
2. Turn the main switch
(A1)
(position
"I"
) to turn on the appliance.
3. Release the button
(A3)
when the default language appears on the display
(A8)
.
4. Set the language of interest using the buttons
(A4-A5)
.
5. Press button
(A7)
to confirm the selection.
Work program selection
1. Press button
(A6)
.
2. Select the program of interest using the buttons
(A4-A5)
.
3. Press button
(A7)
to confirm the selection.
Summary of Contents for TS1
Page 143: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM ...
Page 144: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM ...
Page 145: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM ...
Page 146: ...CATALOGO RICAMBI SPARE PARTS CATALOG ...
Page 147: ...CATALOGO RICAMBI SPARE PARTS CATALOG ...
Page 148: ......
Page 151: ......
Page 153: ......
Page 154: ......