background image

Concepts Serving Systems

Installation Manual

Please read this manual completely before attempting to install or operate this equipment!  
Notify carrier of damage!  Inspect all components immediately.

February 2013

Summary of Contents for Concepts

Page 1: ...cepts Serving Systems Installation Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately February 2013 ...

Page 2: ...ed For Use By Persons Who Lack Experience Or Knowledge Unless They Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety WARNING This Appliance Is Not To Be Played With Warning Do Not Clean With Water Jet WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance CAUTION Observe the following Minimum ...

Page 3: ... intact 7 Freight carriers can supply the necessary damage forms upon request 8 Retain all crating material until an inspection has been made or waived The units with LiquiTec technology cold pans contain a non toxic eutectic fluid within a sealed inner liner This fluid may leak if the tank is punctured so care must be taken when uncrating and setting in place The eutectic fluid is non toxic and m...

Page 4: ...f the unit Always have the serial number of your unit available when calling for parts or service This manual covers standard units only If you have a custom unit consult the customer service department at the number listed below 2013 The Delfield Company All rights reserved Reproduction without written permission is prohibited Delfield is a registered trademarks of The Delfield Company Warranty I...

Page 5: ...cm pipe clamps are useful in pulling equipment tightly together while fasteners are installed This results in a better spline 4 Vise grips will hold backsplash bars together as they are being bolted together 5 A steel hammer and a block of wood can be used to make minor alterations of the stainless steel along the seam between two units in order to perfect the seam This is used after the units are...

Page 6: ...rict exhaust air flow Lift units by ribs at designated places Stickers provided See Photos 1 and 2 2 Study lineup floor plan and utility connections to determine order of installation Place Unit 1 3 Remove the galvanized shipping braces from the bottom of the unit 4 Screw adjustable feet all the way in on the first unit Level to work height usually 36 or as specified 5 Level Unit 1 front to back a...

Page 7: ... on cold pans and hot wells Install hot well control panel 19 Install the kick plate if required by placing the shoulder bolt into the key hole slot See Photo 6 Install screws on end caps as necessary The kick plate will stay in place but can also be easily removed for cleaning under the units 20 Back panels may be removed by unscrewing the hex head screws 21 Install counter protector as necessary...

Page 8: ...d unit 2 bracing hole Secure with a nut Repeat for each hole Do not tighten until Unit 2 is level 9 Level Unit 2 front to back and left to right by adjusting the bullet feet 10 Tighten the nuts and bolts that connect Unit 1 and 2 11 Repeat steps 6 10 as you add each additional unit 12 Have the top installed Verify it is secure and level 13 Plumb drains if necessary 14 Plumb water lines if necessar...

Page 9: ...d with the 2 metallic tabs toward the side of the track with only 1 copper strip the light will not work To correct this simply pull down on the connection box collar and twist it until it is released from the track Then rotate it 180 degrees and mount back into the track using the directions above C To move the light pull down on the connection box collar and twist 90 degrees Slide to the desired...

Page 10: ...the push pins are removed from the mounting brackets in the bottom of the base 3 With a person supporting each post of the signage pick up and hold vertically over top of the collared holes in top 4 If electrical cord is coming out the bottom of one of the posts lower it through the collared hole 5 Next lower signage posts down through collared holes in top 6 Secure in place by sliding push pin th...

Page 11: ...using the directions above To mount flexible spotlights Note The side of the connection post with 2 metallic tabs aligns with the side of the track with the 2 copper strips 1 Pulldownontheconnectionboxcollar pushtheconnection post up into the track and then rotate it 90 degrees until it locks into place 2 If the light is mounted with the 2 metallic tabs toward the side of the track with only 1 cop...

Page 12: ... the fresh water container remove the cap the vinyl tubing is connected to on the container by pressing the button on the cap and pull out the cap from the container Pull the container out of the sink base and unscrew the cap of the fill access hole at the back of the container Fill the container with water and screw the cap back on at the back of the container and push the cap with the vinyl tubi...

Page 13: ... 14 AWG 250C L1 L2 G L3 1000 W 120V OR 1000 1222 W 208 230 V HEATING ELEMENT PILOT LIGHT FURNISHED INFINITE CONTROL WITH OFF POSITION TO ADDITIONAL FOOD WARMERS LINE WIRES P L1 L2 H1 H2 AMPERES IN LINE WIRES 208 230V 3 PHASE OF WARMERS 120V 1 PHASE 208V 1 PHASE 230V 1 PHASE L1 L2 L3 1 8 3 4 8 5 3 2 16 7 9 6 10 6 3 25 14 4 15 9 14 4 15 9 4 33 3 19 2 21 3 5 24 26 6 6 28 8 31 3 19 2 21 3 24 26 1 28 8...

Page 14: ...AN COMPRESSOR 115V L1 N G S C R ON OFF SWITCH CONDENSER FAN COMPRESSOR 115V S C R L1 N G COOLINGT STAT CONDENSER FAN COMPRESSOR 120V L1 N S C R G ON OFF SWITCH Wiring Diagram Self Contained Frost Top Serving Counter Wiring Diagram Self Contained LiquiTec Cold Pan Serving Counter Wiring Diagram Self Contained Mechanically Cooled Serving Counter ...

Page 15: ...Concepts Installation Manual 15 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com Wiring Diagram Tower Module Wiring Diagram Mobile Hand Sink ...

Page 16: ...all 02 13 9291466 Thank you for choosing Delfield Help is a phone call away Help our team of professional courteous customer service reps by having your model number and serial number available at the time of your call 800 733 8829 Model ________________________ S N _______________________ Installation Date ________________ For a list of Delfield s authorized parts depots visit our website at www ...

Reviews: