background image

P/N 07.04.889.00  

© 2019 Hatco Corporation

Glo-Ray

®

Heated Stone Shelves 

保温石板

GRSS, GRSSB, GRSSR Series/

系列

Installation and Operating Manual

安装及操作手册

Do not operate this equipment unless you have read 

and understood the contents of this manual! Failure 

to follow the instructions contained in this manual 

may result in serious injury or death. This manual 

contains important safety information concerning 

the maintenance, use, and operation of this product. 

If you’re unable to understand the contents of this 

manual, please bring it to the attention of your 

supervisor. Keep this manual in a safe location for 

future reference.

English = p 2

WARNING

请在  真阅读并理解本手册的内容后再操作本设
备!不按照本手册中的说明操作可能会导致严重
的人身伤亡事故。本手册中包含了有关本产品维
护、使用和操作的重要安全事项。如果您不理解
本手册的内容,请将本手册交给主管人员,以提
请其注意。请将本手册妥善放置,以便参照。

中文 = 第 

19

 页

hatcocorp.com

Register Online!

(see page 2)

Summary of Contents for Glo-Ray GRSS Series

Page 1: ...t in serious injury or death This manual contains important safety information concerning the maintenance use and operation of this product If you re unable to understand the contents of this manual please bring it to the attention of your supervisor Keep this manual in a safe location for future reference English p 2 WARNING 请在 真阅读并理解本手册的内容后再操作本设 备 不按照本手册中的说明操作可能会导致严重 的人身伤亡事故 本手册中包含了有关本产品维 护 使用和操...

Page 2: ...mends all installation operating and safety instructions appearing in this manual be read prior to installation or operation of a unit Important Owner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 Model Designation 4 Specifications 5 Plug Configurations 5 Electrical Rating Chart 5 Dimensions 7 Installation 9 General 9 GRSS and GRSSR Models 9 GRSSB Models 9 Record ...

Page 3: ...t to active air movements or currents i e near exhaust fans hoods air conditioning ducts and exterior doors WARNING ELECTRIC SHOCK HAZARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install the proper voltage and size electrical receptacle Remote moun...

Page 4: ...ble shelf with an attached 1829 mm 6 cord and plug The portable unit is available in six models GRSS 2418 GRSS 3018 GRSS 3618 GRSS 4818 GRSS 6018 and GRSS 7218 Model GRSS GRSSR Models The GRSSR Heated Stone Shelf is a portable round shelf with an attached 1829 mm 6 cord and plug The portable unit is available in three models GRSSR 16 GRSSR 18 and GRSSR 20 Model GRSSR GRSSB Models The GRSSB Heated ...

Page 5: ...560 6 2 6 6 BS 1363 CEE 7 7 Schuko GRSS 7218 220 1564 7 1 BS 1363 31 kg 68 lbs 220 230 1564 1708 7 1 7 4 BS 1363 CEE 7 7 Schuko 230 240 1708 1860 7 4 7 8 BS 1363 CEE 7 7 Schuko SPECIFICATIONS Electrical Rating Chart GRSS Models Plug Configurations Units are supplied from the factory with an electrical cord and plug installed Plugs are supplied according to the applications WARNING ELECTRIC SHOCK H...

Page 6: ...3 0 BS 1363 16 kg 35 lbs 220 230 655 716 3 0 3 1 CH1 10P BS 1363 CEE 7 7 Schuko 230 240 716 780 3 1 3 3 BS 1363 CEE 7 7 Schuko GRSSB 3618 220 781 3 6 BS 1363 18 kg 40 lbs 220 230 782 854 3 6 3 7 CH1 10P BS 1363 CEE 7 7 Schuko 230 240 854 930 3 7 3 9 BS 1363 CEE 7 7 Schuko GRSSB 4818 220 1068 4 9 BS 1363 23 kg 51 lbs 220 230 1068 1166 4 9 5 1 CH1 10P BS 1363 CEE 7 7 Schuko 230 240 1166 1270 5 0 5 2...

Page 7: ... 25 3 4 349 mm 13 3 4 GRSS 3618 914 mm 36 457 mm 18 64 mm 2 1 2 806 mm 31 3 4 349 mm 13 3 4 GRSS 4818 1220 mm 48 457 mm 18 159 mm 6 1 4 1086 mm 42 3 4 324 mm 12 3 4 GRSS 6018 1524 mm 60 457 mm 18 159 mm 6 1 4 1391 mm 54 3 4 324 mm 12 3 4 GRSS 7218 1828 mm 72 457 mm 18 159 mm 6 1 4 1695 mm 66 3 4 324 mm 12 3 4 Dimensions A D E B C Front View Side View Height includes 102 mm 4 legs Dimensions GRSS M...

Page 8: ...18 1870 mm 73 5 8 498 mm 19 5 8 57 mm 2 1 4 Dimensions GRSSB Models NOTE See the OPTIONS AND ACCESSORIES section for dimension information for flush style remote mounted control enclosures NOTICE Refer to the installation section of this manual for actual countertop cutout dimensions Model Diameter A Height B GRSSR 16 406 mm 16 67 mm 2 5 8 GRSSR 18 457 mm 18 67 mm 2 5 8 GRSSR 20 508 mm 20 67 mm 2 ...

Page 9: ...eadily removable not permanently mounted continued General Use the following procedures to install the GRSS GRSSR and GRSSB units WARNING ELECTRIC SHOCK HAZARD Unit is not weatherproof Locate unit indoors where ambient air temperature is a minimum of 21 C 70 F FIRE HAZARD Locate unit a minimum of 25 mm 1 from combustible walls and materials If safe distances are not maintained discoloration or com...

Page 10: ... it does not hang down GRSSB Built In Installation Trim Mounting Ring Countertop Apply a bead of NSF approved sealant between the countertop material and trim mounting ring Sealant must be rated for use at a minimum temperature of 121 C 250 F GRSSB Countertop Cutout Chart Model Width Depth GRSSB 2418 625 mm 24 5 8 632 mm 24 7 8 473 mm 18 5 8 479 mm 18 7 8 GRSSB 3018 778 mm 30 5 8 784 mm 30 7 8 473...

Page 11: ...on when touching these areas 4 Turn the Temperature Control to the desired temperature setting Turning the Temperature Control knob clockwise will increase the temperature setting Turning the Temperature Control knob counterclockwise will decrease the temperature setting 5 Allow the unit 30 minutes to reach operating temperature NOTE Refer to the OPTIONS AND ACCESSORIES section for installation an...

Page 12: ...g on the unit each day clean and sanitize the stone surfaces using a clean damp cloth and a sanitizer approved for food contact surfaces If additional cleaning is necessary refer to the Cleaning the Stone Surface information in this section 2 At the end of each day a Turn off the unit and allow to cool b Wipe down all metal surfaces using a clean damp non abrasive cloth c Clean and sanitize the st...

Page 13: ...being cleaned properly Clean surface using the Cleaning the Stone Surface information in the MAINTENANCE section of this manual If these methods fail to produce acceptable results contact Hatco for assistance Shelf is flexing Excessive weight on shelf Distribute weight evenly on entire shelf If weight on the shelf exceeds 23 kg 50 lbs a deflection up to 4 mm 5 32 is possible If weight on the shelf...

Page 14: ...stalling the 102 mm 4 Legs 4 At each corner of the base screw a 102 mm 4 leg into the bottom of the base NOTE The feet on the 102 mm 4 legs are adjustable for leveling the unit Use a 16 mm 5 8 open end wrench to make leveling adjustments once the unit is placed in its final position Handles GRSS Models only Designer black powdercoated rounded stainless steel handles are available for GRSS models T...

Page 15: ... They are available in 76 mm 3 and 127 mm 5 heights in several colors and in stainless steel To install the riser 1 Place the riser in the desired location on the countertop 2 Thread the power cord of the GRSSR unit through one of the access holes in the riser 3 Set the GRSSR unit inside the riser Make sure the controls are accessible through one of the access holes in the riser Access Hole Model ...

Page 16: ...through the backside 4 Secure control enclosure to mounting surface using screws not supplied 5 Connect proper power source to the mounted remote control enclosure 6 Reinstall trim cover NOTE Units are equipped with a 914 mm 3 flexible conduit connecting the control enclosure to the unit The digital temperature controller also offers 1829 mm 6 and 3048 mm 10 conduit lengths Power I O on off Switch...

Page 17: ...w setpoint temperature The TEMPERATURE display will go blank for two seconds to show that the new setting has been accepted NOTE After 10 seconds of inactivity during the programming process the controller will exit programming mode automatically without saving any changes SET Key Up Arrow Key Down Arrow Key Display Digital Temperature Controller Changing Fahrenheit and Celsius Setting Digital Tem...

Page 18: ...mical attack or freezing or Product misuse tampering or misapplication improper installation or application of improper voltage 2 LIMITATION OF REMEDIES AND DAMAGES Hatco s liability and Buyer s exclusive remedy hereunder will be limited solely to replacement of part or Product using at Hatco s option new or refurbished parts or Product by Hatco or a Hatco authorized service agency with respect to...

Page 19: ... 简介 19 重要安全事项 20 型号说明 21 型号命名 21 规格 22 插头型式 22 电气参数表 22 尺寸 24 安装 26 总则 26 GRSS 和 GRSSR 型号 26 GRSSB 型号 26 请在下列空白处记下本设备的型号 序列号 电压 和购买日 期 规格标签在 GRSS 和 GRSSR 型号的底部 GRSSB 型 号的控制箱底部 致电 Hatco 要求服务帮助时请提供上述信 息 型号__________________________________________________ 序列号________________________________________________ 电压__________________________________________________ 购买日期_____________________________________...

Page 20: ...避免将设备放于空气流动 或气流活跃的区域 即靠近排气扇 排风罩 空调管和外门处 触电危险 将设备插头妥善插入有接地的电气插座内 插入前请核对电 压 规格和插头型式是否正确 如果插头和插座不匹配 请 和有正式资格的电工联系 以确定并安装电压和规格正确的 电气插座 对设备进行清洗 调整 或维修前 请切断电源 拔掉电源 线 并让设备冷却 不得将设备浸入水中 本设备不具备防水性能 如果设备被 水浸泡 不得进行操作 设备不防水 将该设备放于室内 周围空气温度保持最低 21 C 70 F 最高 45 C 113 F 不得用蒸汽或使用过多的水清洁本设备 本设备不具备 防喷淋 结构 请勿使用喷淋头清洁本设 备 请勿用电源线拖拽本设备 如果电源线出现磨损 请停止使用 请勿试图维修或更换损坏的电源线 电源线必须由 Hatco Hatco 授权服务机构或具备类似资格的人 负责更换 该设备必须只由合格人员进行操作...

Page 21: ... GRSS 保温石板是随附 1829 mm 6 电线和插头的便携 式板 该便携式设备有六种型号可供选择 GRSS 2418 GRSS 3018 GRSS 3618 GRSS 4818 GRSS 6018 和 GRSS 7218 GRSS 型号 GRSSR 型号 GRSSR 保温石板是随附 1829 mm 6 电线和插头的便携式 圆形板 该便携式设备有三种型号可供选择 GRSSR 16 GRSSR 18 和 GRSSR 20 GRSSR 型号 GRSSB 型号 GRSSB 保温石板是配备随附装饰安装环的嵌入式设备 该设 备包含随附 914 mm 3 导管的遥控控制箱 1829 mm 6 带 插头的电源线将遥控控制箱与电源连接 该嵌入式设备有六种型号可供选择 GRSSB 2418 GRSSB 3018 GRSSB 3618 GRSSB 4818 GRSSB 6018 和 GRSSB 7218 ...

Page 22: ... BS 1363 20 kg 45 lbs 220 230 1068 1166 4 9 5 1 BS 1363 CEE 7 7 Schuko 230 240 1166 1270 5 0 5 2 BS 1363 CEE 7 7 Schuko GRSS 6018 220 1310 6 0 BS 1363 25 kg 56 lbs 220 230 1310 1432 6 0 6 2 BS 1363 CEE 7 7 Schuko 230 240 1432 1560 6 2 6 6 BS 1363 CEE 7 7 Schuko GRSS 7218 220 1564 7 1 BS 1363 31 kg 68 lbs 220 230 1564 1708 7 1 7 4 BS 1363 CEE 7 7 Schuko 230 240 1708 1860 7 4 7 8 BS 1363 CEE 7 7 Sch...

Page 23: ...6 BS 1363 CEE 7 7 Schuko GRSSB 3018 220 655 3 0 BS 1363 16 kg 35 lbs 220 230 655 716 3 0 3 1 CH1 10P BS 1363 CEE 7 7 Schuko 230 240 716 780 3 1 3 3 BS 1363 CEE 7 7 Schuko GRSSB 3618 220 781 3 6 BS 1363 18 kg 40 lbs 220 230 782 854 3 6 3 7 CH1 10P BS 1363 CEE 7 7 Schuko 230 240 854 930 3 7 3 9 BS 1363 CEE 7 7 Schuko GRSSB 4818 220 1068 4 9 BS 1363 23 kg 51 lbs 220 230 1068 1166 4 9 5 1 CH1 10P BS 1...

Page 24: ...m 2 1 2 654 mm 25 3 4 349 mm 13 3 4 GRSS 3618 914 mm 36 457 mm 18 64 mm 2 1 2 806 mm 31 3 4 349 mm 13 3 4 GRSS 4818 1220 mm 48 457 mm 18 159 mm 6 1 4 1086 mm 42 3 4 324 mm 12 3 4 GRSS 6018 1524 mm 60 457 mm 18 159 mm 6 1 4 1391 mm 54 3 4 324 mm 12 3 4 GRSS 7218 1828 mm 72 457 mm 18 159 mm 6 1 4 1695 mm 66 3 4 324 mm 12 3 4 A D E B C ဇ ف ဇ 高度包括 102 mm 4 脚架 尺寸 GRSS 型号 规格 ...

Page 25: ...98 mm 19 5 8 57 mm 2 1 4 GRSSB 4818 1260 mm 49 5 8 498 mm 19 5 8 57 mm 2 1 4 GRSSB 6018 1565 mm 61 5 8 498 mm 19 5 8 57 mm 2 1 4 GRSSB 7218 1870 mm 73 5 8 498 mm 19 5 8 57 mm 2 1 4 尺寸 GRSSR 型号 尺寸 GRSSR 型号 尺寸 GRSSB 型号 注意 请参阅 选件及附件 部分了解平接型壁挂遥控控制 盒的尺寸信息 请参阅本手册的安装部分了解实际工作台面开口尺寸 型号 直径 A 高度 B GRSSR 16 406 mm 16 67 mm 2 5 8 GRSSR 18 457 mm 18 67 mm 2 5 8 GRSSR 20 508 mm 20 67 mm 2 5 8 A B ݾ ဇ ف ဇ A B D E...

Page 26: ...些松弛 注意 应将螺丝头直径至少为 6 mm 1 4 的螺丝插入安装支 架上的键孔 来安装遥控控制箱 遥控控制箱易于拆 卸 并非永久安装 总则 请使用以下程序安装 GRSS GRSSR 和 GRSSB 设备 触电危险 本设备不具备耐候性 请将本设备置于室内 室内 气温不得低于 21 C 70 F 着火危险 本设备距离可燃墙壁或材料应至少有 25 mm 如果不能保 持上述安全距离 则可能引起褪色或燃烧 将设备置于便于使用的区域 并使其处于适宜的台面高度 放 置位置应保持水平 以防设备或承装物意外跌落 还应有足够 的强度 以承受设备和承装物的重量 美国国家卫生基金会 NSF 要求对宽度超过 914 毫米 36 英 寸 或重量超过 36 公斤 80 磅 的设备进行密封 或抬升 到安装表面上方 如果不能在使用点密封设备 则应包括 102 mm 4 脚架 以便允许在设备下方进行合适的清洁检 修 不要...

Page 27: ...ਥܿ߇ ށ ቂᏥ ၫ ޡ כ ᅐ 121 C 250 F ȃ GRSSB 工作台面开口图 型号 宽度 A 深度 B GRSSB 2418 625 mm 24 5 8 632 mm 24 7 8 473 mm 18 5 8 479 mm 18 7 8 GRSSB 3018 778 mm 30 5 8 784 mm 30 7 8 473 mm 18 5 8 479 mm 18 7 8 GRSSB 3618 930 mm 36 5 8 937 mm 36 7 8 473 mm 18 5 8 479 mm 18 7 8 GRSSB 4818 1235 mm 48 5 8 1241 mm 48 7 8 473 mm 18 5 8 479 mm 18 7 8 GRSSB 6018 1540 mm 60 5 8 1546 mm 60 7 8 473 mm 18 5 8 479 mm 18 7 8 GRS...

Page 28: ...参见本手册的 规格 部分了解详细信息 3 将电源 I O 打开 关闭 开关移至 I 打开 位置 着火危险 本设备的某些外表面处温度较高 接触这些部位时 请务必小心 4 将温度控制器转至所需的温度设置 顺时针转动温度控制器旋钮将升高温度设置 逆时针转 动温度控制器旋钮将降低温度设置 5 等待 30 分钟以使设备达到运行温度 注意 请参阅 选件及附件 部分了解有关配备平接型壁挂遥控 控制面板的 GRSSB 设备的安装和操作信息 如果板上的重量超过 23 kg 50 lb 则最多可能弯曲 4 mm 5 32 如果板上的重量超过 45 kg 100 lb 则可能弯曲 6 mm 1 4 如果板上的重量超过 68 kg 150 lb 则无法保 证板的使用 所有重量均应均匀分布在整个板上 ݢ ኑ I O 0 ט ၫ ޡ 标准控制面板 GRSS 型号 ...

Page 29: ...剂和抹布清洁设备 带腐蚀性的清洁剂 和抹布会划伤设备表面 影响外观 同时容易积污垢 1 每天启动设备前 使用干净湿布和批准用于食品接触表面 的消毒杀菌剂对石材表面进行清洁和消毒 如果需要额 外清洁 请参阅本部分的 清洁石材表面 信息 2 每天结束时 a 关闭设备并让其冷却 b 使用干净柔软的湿布擦拭所有金属表面 c 使用干净湿布和批准用于食品接触表面的消毒杀菌剂对 石材表面进行清洁和消毒 如果需要额外清洁 请参 阅本部分的 清洁石材表面 信息 注意 若要纠正不一致的染色和脱色 请参阅本部分的 清洁 石材表面 信息 d 使用干净的软布擦干 清洁石材表面 正确使用下面列出的产品不会损坏石材表面 遵循产品标签上 的指示 注意 石材表面是仿造石材固体表面 使用研磨材料深度清洁表面后以及将食品放置到设备上之前 确保对石材表面进行正确清洁和消毒 难以清除的污渍 对 于 难 以 清 除 的 污 渍 使 ...

Page 30: ...或有不一 致的染色 脱色 未正确清洁石材表面 使用本手册 维护 部分的 清洁石材表面 信息清洁表 面 如果这些方法无法产生可接受的结果 则联系 Hatco 寻求帮助 板弯曲 板上的重量过高 让重量在整个板上均匀分布 如果板上的重量超过 23 kg 50 lb 则最多可能弯曲 4 mm 5 32 如果板上的重量超 过 45 kg 100 lb 则可能弯曲 6 mm 1 4 如果板上的 重量超过 68 kg 150 lb 则无法保证板的使用 故障处理指南 本设备只能由受过培训且具备相应资格的人员负责维修 若由 不具备相应资格的人员维修 则可能引起触电或着火 触电危险 对设备进行清洗 调整 或维修前 请切断电源 拔掉电源线 并让设备冷却 对问题进行故障针对 如果您的困境在问题解决后仍无法解除 请联系距您最近的经过授权的服务代理或 Hatco 以寻求帮助 请查找最近的服务机构 请登录 Hatco ...

Page 31: ...备冷却 2 小心地将本机倒置 并将其放置在平面上 确保用东西盖 住表面 防止刮擦石材表面 3 在底座的每个角上 取下底脚螺丝和橡胶底脚 102 mm 4 ਰ৩ 安装 102 mm 4 脚架 4 在底座的每个角上 将 102 mm 4 脚架拧到底座底部 注意 102 mm 4 脚架上的底脚可以调节 从而调平设备 在设备处于最终位置之后 使用 16 mm 5 8 开口扳手 进行水平调整 手柄 仅限 GRSS 型号 GRSS 型号有设计师黑色粉末涂层圆形不锈钢手柄可供选择 手柄可现场改造并且使用下列程序安装到设备的每端 在设备的每端 1 取下石材表面支撑环下面的三个螺母 2 将手柄上的三个孔与支撑环上的三个螺栓对齐 然后将手 柄置于螺栓上 3 将三个螺母重新拧到螺栓上 并牢固拧紧 ፀ ڄ ० ఞವ ఞ 手柄安装 GRSSB 型号的凹顶 GRSSB 型号有可选凹顶可供选择 具有凹顶的设备可让保温 ...

Page 32: ...SR 20 533 mm 21 400 mm 15 3 4 砧板 仅限 GRSSB 型号 砧板底部配备橡胶底脚以将其置于设备中心 制成砧板的材料与保温石板表面相同 有不同颜色可供选择 砧板 砧板 立板 仅限 GRSSB 型号 可提供钢立板以增加 GRSSR 设备的高度 材质为不锈钢 有 76 mm 3 和 127 mm 5 的高度以及不同颜色可供选择 若要安装立板 1 将立板放在工作台面上的所需位置 2 将 GRSSR 设备的电源线穿过立板的其中一个检修孔 3 将 GRSSR 设备置于立板内 确保可通过立板的其中一个 检修孔触及控制器 ᅃ 型号 GRSSR 127 mm 5 立板 A B 砧板 选项和配件 ...

Page 33: ...螺丝孔 2 从控制盒总成卸下装饰盖板 3 通过背面将控制盒定位在开口中 4 使用螺丝 未提供 将控制盒固定到安装表面 5 将合适的电源连接到壁挂遥控控制盒 6 重新安装装饰盖板 注意 设备配备一根 914 mm 3 柔性导管 后者将控制盒连 接到设备 数字温度控制器还提供 1829 mm 6 和 3048 mm 10 的导管长度 电源 I O 打开 关闭 开关 两种平接型壁挂遥控控制盒配备电源 I O 打开 关闭 开关 将电源 I O 打开 关闭 开关移至 I 打开 位置可打开设备 当设备打开时 开关中的指示灯发光 更改设定温度 机械温度控制 顺时针转动温度控制器可升高设定温度 逆时针转动温度控制 器可降低设定温度 ၫ ޡ ݢ ኑ I O 0 ט 机械温度控制 ᄚၫ ޡ 102 mm 4 Ꮝၫ ޡ ධ 121 mm 4 3 4 Ꭷ װ ಅ Ꭷ ड 149 mm 5 7 8 98 mm 3 ...

Page 34: ...定温度将显示在温度显示屏上 按两下按键后将显示 SP 2 按 按键或 长按 10 秒可更改设定温度 3 按 按键以锁定新的设定温度 温度显示屏将变为空白 两秒钟 以显示新设置已被接受 注意 编程过程中无任何操作超过 10 秒钟 则控制器将自动 退出编程模式 且不保存任何更改 SET 按键 向上箭头按键 向下箭头按键 显示 数字温度控制器 更改华氏和摄氏温度设置 数字温度控制器 按照以下程序将显示屏在华氏温度和摄氏温度之间进行更改 1 按 一下按键 显示 F 表示为华氏温度 显示 C 则表 示为摄氏温度 2 按 按键或 长按按键 10 秒以在 F 华氏温度 和 C 摄氏温度 之间进行更改 3 按 三下按键以锁定新的设置 温度显示屏将变为空白 两秒钟 以显示新设置已被接受 注意 编程过程中无任何操作超过 10 秒钟 则控制器将自动 退出编程模式 且不保存任何更改 选项和配件 ...

Page 35: ...热灯泡 带涂层卤素 灯泡 卤素加热灯泡 氙气灯泡 LED光管 玻璃组件和保险 丝 由于结垢 化学腐蚀或严寒造成的瞬时加热器水箱 翅片 管式换热器或其他水加热设备的故障 或产品使用不当 擅自 改动或误用 安装不当 或电压不正确 2 修复和损坏限制 本文所述赫高责任以及对用户的独家修复补偿义务仅限于在上 述保修期内提出索赔 由赫高或赫高授权的服务机构负责更换 新零件或产品或对原零件或产品进行维修 赫高有权接受或拒 绝任何此类全部或部分的索赔 在此有限质保规定中 翻新 是指本产品的部分或整机已经被赫高或赫高授权的服务代理机 构修复至原有的产品规格 未经赫高事先书面批准 赫高不接 受任何产品的退回 经过赫高同意的产品退回 其相关费用均 由用户独自承担 在任何情况下 对于因故或意外而引起的损 失 包括但不限于人工费用 或因产品的使用 或不会用 或 产品隶属或成为其他产品的一部分而造成的利润损失 赫高...

Page 36: ...IPMENT SUZHOU CO LTD Unit A No 9 Weixin Road Suzhou Industrial Park Jiangsu China Telephone 0512 6732 5091 infocn hatcocorp com www hatcocorp com HATCO CORPORATION P O Box 340500 Milwaukee WI 53234 0500 U S A Telephone 1 414 671 6350 support hatcocorp com www hatcocorp com ...

Reviews: