16
Form No. GRSSM_CN-0919
English
Remote Mounted Control Enclosures
(GRSSB Models only)
Two flush-style remote mounted control enclosures are available
for the GRSSB model — the Mechanical Temperature Control
enclosure and the Digital Temperature Controller enclosure.
Both enclosures are installed using the following procedure.
WARNING
ELECTRIC SHOCK HAZARD: Remote mounted control
enclosure must be mounted on a vertical wall and
installed in vertical position. Mounting control enclosure
in horizontal position may result in collection of liquids
and lead to an electric shock.
NOTICE
Install remote mounted control enclosure outside of heat
zone. Locating control enclosure inside heat zone will
cause control(s) to overheat, malfunction, and fail.
Do not modify wiring or cut thermostat capillary on
control box to increase remote mounting distance. Cutting
thermostat capillary will cause unit to overheat and may
damage unit as well as surrounding countertop.
NOTE: A qualified electrician is recommended for connecting
the units to a power source.
1. Prepare cutout and pre-drill screw holes.
2. Remove trim cover from control enclosure assembly.
3. Position control enclosure into opening through the backside.
4. Secure control enclosure to mounting surface using
screws (not supplied).
5. Connect proper power source to the mounted remote
control enclosure.
6. Reinstall trim cover.
NOTE: Units are equipped with a 914 mm (3′) flexible conduit
connecting the control enclosure to the unit. The digital
temperature controller also offers 1829 mm (6′) and
3048 mm (10′) conduit lengths.
Power I/O (on/off) Switch
Both flush-style remote mounted control enclosures are
equipped with a Power I/O (on/off) switch. Move the Power
I/O (on/off) switch to the I (on) position to turn on the unit. The
indicator light in the switch glows when the unit is on.
Changing the Setpoint Temperature — Mechanical
Temperature Control
Turn the temperature control clockwise to increase the setpoint
temperature. Turn the temperature control counterclockwise to
decrease the setpoint temperature.
Temperature
Control
Power I/O (on/off) Switch
Mechanical Temperature Control
Mechanical Temperature Control
102 mm (4″)
Digital Temperature Controller
121 mm (4-3/4″)
Mounting Surface
Trim Cover
Control Enclosure
149 mm
(5-7/8″)
98 mm
(3-7/8″)
162 mm
(6-3/8″)
174 mm
(6-7/8″)
Side View of Installed Enclosure
Front View of Cutout
Optional Remote Mounted Control Enclosure Installation Dimensions
IMPORTANT NOTE
Make sure the installation
location provides enough
room for electrical
connections to the control
enclosure.
OPTIONS AND ACCESSORIES