Falcon R-Class | User Guide
178
SyncE Configuration
SSM Option Select
Select the system network region option:
•
SSM Option 1 - refers to synchronization networks designed for Europe.
•
SSM Option 2 - refers to synchronization networks designed for US.
SSM Free Run
Set the SSM output quality level in Free Run state: PRC, SSUB, SSUA, EEC1, DNU
SSM Holdover
Set the SSM output quality level in Holdover state: PRC, SSUB, SSUA, EEC1, DNU
Figure 4-128: SyncE Port Configuration
Table 4-121: SyncE Port Configuration Parameters
SyncE Ports
Port
The port number to configure.
SSM Enable
Enable and disable of SSM functionality on this port.
Tx SSM: Quality Level Monitoring of the transmitted SSM QL on this port. Transmitted QL should be
the Quality Level of the clock generated by this node. This means the QL of the
clock source this node is locked to.
Tx SSM: SSM code
(hex)
Displaying the actual hex code used to indicate the transmitted Quality.