Table 4-92: Configuration parameters
General/Frequency/Phase/ToD Configuration
Mode
Allow
selection
of
the
required
system’s
synchronization
mode
Available modes are:
•
Manual:
source will the one configured in the manual source configuration
fields, regardless of its state.
•
Auto Revertive (default mode).:
clock source is automatically selected based
on priority and state. When higher priority source that previously failed, is valid
again, switchover will take place. This is the default mode and the most
commonly used one.
•
Auto Non-Revertive:
clock source is automatically selected based on priority
and state. When higher priority source that previously failed, is valid again, no
switchover will take place.
•
Forced HoldOver:
the system will be synchronized to the last selected source
but will go into holdover mode and ignore this source.
•
Forced Free running
:
the system will be synchronized to the local clock,
ignoring all sync sources.
Priority Select
Mode
The source will be selected based on its ID (the lower it is the higher its priority) or
based on its Quality.
Manual Sync
Source ID
Manually configure the sync source. Applicable only in Manual mode.
WTR
Configure the Wait To Restore (WTR) timer or disable its operation (applicable
when in Auto-Revertive mode).
Holdover Configuration
Figure 4-98: Holdover Configuration