Falcon R-Class | User Guide
179
Rx SSM: Quality Level Monitoring of the received SSM QL on this port. If link is down on port, QL_LINK
is indicated. If no SSM is received, QL_FAIL is indicated.
Rx SSM: SSM code
(hex)
1000BaseT Mode
If PHY is in 1000BaseT Mode then this is monitoring the master/slave mode. In
order to receive clock on a port, it has to be in slave mode. In order to transmit
clock on a port, it has to be in master mode.
SyncE Port Monitoring
This section displays and allows configuration of the SyncE configuration of the applicable Ethernet
ports.
Web GUI: Monitor > Timing > SyncE
Figure 4-129: SyncE Status
Table 4-122: SyncE Status Parameters
SyncE Status
SSM Option Select
Display the system network region option:
•
SSM Option 1 - refers to synchronization networks designed for Europe.
•
SSM Option 2 - refers to synchronization networks designed for US.
SSM Free Run
Display SSM output quality level in Free Run state: PRC, SSUB, SSUA, EEC1, DNU
SSM Holdover
Display SSM output quality level in Holdover state: PRC, SSUB, SSUA, EEC1, DNU
Table 4-123: SyncE Port Status Parameters
SyncE Ports Status
Port
The port number to configure.
Tx SSM: Status
Idicate and disable of SSM functionality on this port.