CiTRANS R820 Edge Router Hardware Description
Table 6-11
Connection Method of the Alarm Cable of the Head of Row Cabinet
Cable Name
Terminal
Connected to
Alarm cable of the head of
row cabinet
Three-core D-type connector
XPB1 on the PDP
Three-core cable
Head of row cabinet
Technical Parameters
Table 6-12 lists technical parameters of the alarm cable of the head of row cabinet.
Table 6-12
Technical Parameters of the Alarm Cable of the Head of Row Cabinet
Item
Specification
Cable type
AVVR
Color
Brown/black/blue
Maximum current (A)
3
Conductor cross-sectional area (mm
2
)
3 0.5
6.3.2
Subrack Alarm Cable
The following introduces the model, usage, structure, connection method, and
technical parameters of the subrack alarm cable.
Model
The model of the subrack alarm cable is 3.695.095.
Usage
The subrack alarm cable connects a subrack to the PDP and outputs the subrack
alarms to the PDP.
Structure
The subrack alarm cable is a straight-through cable, as shown in Figure 6-6.
6-10
Version: A