5.3 Diagnosing with WinPISA
With the command [Diagnosis][Status display] in the
menu [Online] you can display important system data of
the SPC200. The register card [Field bus] shows infor-
mation on the field bus connection.
Fig. 5/1: WinPISA status display "Field bus"
Status
Description
Field bus type
Protocol of the installed field bus module
Connection
Parametrizing:
No connection to field bus (baud rate search),
Configuring:
Waits for configuration by the PROFIBUS master,
Data exchange:
Data exchange runs
Bus address
Set Profibus address
Baud rate
Current baud rate of PROFIBUS-DP network
1)
I/O assignment
Number of I/O bytes used for communication
2)
Software version
Software version number of field bus module
Info
Information (Sync/Freeze active; baud search;
configuration error from master)
1) When connection is being made, the display changes continuously until the SPC200
can ascertain the baud rate of the PROFIBUS-DP network.
2) The entry 0I/0O-byte means that an I/O field size has not yet been specified by the
master.
5. Diagnosis and error treatment
5-6
SPC200-COM-PDP 9904NH
Summary of Contents for SPC200 Series
Page 1: ...Smart Positioning Controller SPC200 Fieldbus module PROFIBUS DP Type SPC200 COM PDP ...
Page 11: ...X SPC200 COM PDP 9904NH ...
Page 12: ...Chapter 1 System summary 1 System summary SPC200 COM PDP 9904NH 1 1 ...
Page 22: ...Chapter 2 Fitting 2 Fitting SPC200 COM PDP 9904NH 2 1 ...
Page 28: ...Chapter 3 Installation 3 Installation SPC200 COM PDP 9904NH 3 1 ...
Page 38: ...Chapter 4 Commissioning 4 Commissioning SPC200 COM PDP 9904NH 4 1 ...
Page 100: ...Appendix A Technical appendix A Technical appendix SPC200 COM PDP 9904NH A 1 ...
Page 103: ...A Technical appendix A 4 SPC200 COM PDP 9904NH ...
Page 107: ...A Technical appendix A 8 SPC200 COM PDP 9904NH ...