With the field bus module, 10 bits are available for se-
lecting the NC record number in record select mode.
The maximum permitted number of NC records (up to
1000) of the determined starting programs can there-
fore be accessed.
When a field bus module is used:
•
the address ranges I0.0 ... I0.9 and Q0.0 ... Q0.7 re-
main unused. These address ranges, which serve
without field bus module for controlling the SPC200,
are not available.
•
maximum 3 I/O modules can be inserted. These pro-
vide exclusively freely programmable I/Os in the
operating mode start/stop.
The address assignment when a field bus module is
used is shown in the table below.
Module
Maximum address range
-
1)
I0.0 ...I0.9
1)
Q0.0 ... Q0.7
1)
I/O modules on first
axis interface string
I1.0 ... I1.15
Q1.0 ... Q1.15
First I/O module
I2.0 ... I2.9
Q2.0 ... Q2.7
I/O modules on second
axis interface string
I3.0 ... I3.15
Q3.0 ... Q3.15
Second I/O module
I4.0 ... I4.9
Q4.0 ... Q4.7
Third I/O module
I5.0 ... I5.9
Q5.0 ... Q5.7
Field bus module
I10.0 ... I13.15
Q10.0 ... Q13.15
1) Address range is not available if a field bus module
is used
1. System summary
SPC200-COM-PDP 9904NH
1-9
Summary of Contents for SPC200 Series
Page 1: ...Smart Positioning Controller SPC200 Fieldbus module PROFIBUS DP Type SPC200 COM PDP ...
Page 11: ...X SPC200 COM PDP 9904NH ...
Page 12: ...Chapter 1 System summary 1 System summary SPC200 COM PDP 9904NH 1 1 ...
Page 22: ...Chapter 2 Fitting 2 Fitting SPC200 COM PDP 9904NH 2 1 ...
Page 28: ...Chapter 3 Installation 3 Installation SPC200 COM PDP 9904NH 3 1 ...
Page 38: ...Chapter 4 Commissioning 4 Commissioning SPC200 COM PDP 9904NH 4 1 ...
Page 100: ...Appendix A Technical appendix A Technical appendix SPC200 COM PDP 9904NH A 1 ...
Page 103: ...A Technical appendix A 4 SPC200 COM PDP 9904NH ...
Page 107: ...A Technical appendix A 8 SPC200 COM PDP 9904NH ...