Plugs
CAUTION
Use plugs with a terminating resistor if you are fitting
the SPC200 at the end of a segment.
Use special bus plugs for PROFIBUS, e.g. the following
9-pin plug from Siemens AG or from ERNI.
Siemens part number
Description
6ES7 972-0BA10-0XA0
Terminating resistor can be switched
in; vertical cable exit;
Baud rate 9.6 kBaud...12 MBaud;
4-pin series terminals for wires up to
1.5 mm
2
6ES7 972-0BB10-0XA0
As above, but also with
conduit thread connection
ERNI part number
Description
103648
Horizontal cable exit;
Baud rate 9.6 kBaud...12 MBaud;
4-pin series terminal for wires up to
1.5 mm
2
103649
As above, but with integrated
terminating resistor
3. Installation
3-6
SPC200-COM-PDP 9904NH
Summary of Contents for SPC200 Series
Page 1: ...Smart Positioning Controller SPC200 Fieldbus module PROFIBUS DP Type SPC200 COM PDP ...
Page 11: ...X SPC200 COM PDP 9904NH ...
Page 12: ...Chapter 1 System summary 1 System summary SPC200 COM PDP 9904NH 1 1 ...
Page 22: ...Chapter 2 Fitting 2 Fitting SPC200 COM PDP 9904NH 2 1 ...
Page 28: ...Chapter 3 Installation 3 Installation SPC200 COM PDP 9904NH 3 1 ...
Page 38: ...Chapter 4 Commissioning 4 Commissioning SPC200 COM PDP 9904NH 4 1 ...
Page 100: ...Appendix A Technical appendix A Technical appendix SPC200 COM PDP 9904NH A 1 ...
Page 103: ...A Technical appendix A 4 SPC200 COM PDP 9904NH ...
Page 107: ...A Technical appendix A 8 SPC200 COM PDP 9904NH ...