3.1 General instructions
WARNING
Before undertaking installation and/or maintenance
work, switch off the following in the sequence speci-
fied here:
1. the compressed air supply
2. – the load voltage supply for field devices and
proportional directional control valves
(plug X2, pin 1)
– the load voltage supply for the outputs
(plug X6/X8, pin 8)
– if applicable, the load voltage supply for the
axis interface string
– the operating voltage supply for internal
electronics of the SPC200 and field devices
(plug X2, pin 2).
You thereby avoid:
– undesired movements of the connected actuators
– uncontrolled movements of loose tubing
– undefined switching states
CAUTION
Please note that the maximum permitted bus seg-
ment length depends on the baud rate used.
A bus segment is a bus cable which may contain up to
32 slaves (devices). The ends of the bus segment must
be sealed with a terminating resistor. Use plugs with an
integrated terminating resistor if you are fitting the
SPC200 to the end of a bus segment.
3. Installation
SPC200-COM-PDP 9904NH
3-3
Summary of Contents for SPC200 Series
Page 1: ...Smart Positioning Controller SPC200 Fieldbus module PROFIBUS DP Type SPC200 COM PDP ...
Page 11: ...X SPC200 COM PDP 9904NH ...
Page 12: ...Chapter 1 System summary 1 System summary SPC200 COM PDP 9904NH 1 1 ...
Page 22: ...Chapter 2 Fitting 2 Fitting SPC200 COM PDP 9904NH 2 1 ...
Page 28: ...Chapter 3 Installation 3 Installation SPC200 COM PDP 9904NH 3 1 ...
Page 38: ...Chapter 4 Commissioning 4 Commissioning SPC200 COM PDP 9904NH 4 1 ...
Page 100: ...Appendix A Technical appendix A Technical appendix SPC200 COM PDP 9904NH A 1 ...
Page 103: ...A Technical appendix A 4 SPC200 COM PDP 9904NH ...
Page 107: ...A Technical appendix A 8 SPC200 COM PDP 9904NH ...