Send parametrizing data (Set_Prm)
The parametrizing data is transferred from the DP mas-
ter to the SPC200 with the function Set_Prm.
Octet 1: Station status
Bit
Meaning
Explanation
0
-
Reserved
1
-
2
-
3
WD_On
Response monitoring of SPC200 on/off:
logic "0": off
logic "1": on
4
Freeze_Req
logic "1": Activate FREEZE
5
Sync_Req
log. "1": Activate SYNC
Bit 7
Bit 6
Explanation
6
7
Unlock_Req
Lock_Req
0
0
min T
SDR
+ SPC200 parameter
may be overwritten
0
1
Release SPC200 for other masters
1
0
SPC200 blocked for other masters
1
1
Release SPC200 for other masters
4. Commissioning
SPC200-COM-PDP 9904NH
4-31