SOPA-...
Festo – SOPA-... – 2017-09b English
43
12
Quick commissioning
Switch on the operating voltage.
è
The sensor modules are automatically set to RUN mode.
Note
If you are unsure as to whether a sensor module is in RUN mode:
Press and hold the Edit button for 3 seconds. The sensor module switches to
RUNmode.
The switching output Out A is used for distance monitoring. In the event of a quick commissioning
procedure, you will need to set or teach-in the switching point for Out A.
Option 1: Manually setting the switching point for Out A
1. Press the Edit button.
è
The EDIT mode is active. [Out A] flashes or [Lock] flashes if there is an active security lock
(release security lock
è
Chapter 5.6.2).
2. Press the Edit button again to confirm the selection.
è
[SP] flashes.
3. Set the switching point by using the A/B pushbuttons.
4. Press and hold the Edit button for 3 seconds.
è
The sensor module switches to RUN mode.
Option 2: Teaching-in the switching point for Out A
1. Set the desired sensing distance between the object and measuring nozzle.
2. First press the A pushbutton and then the Edit button as well.
[Out A] and [TeachIn] flash.
3. Release both pushbuttons.
è
The value is transferred as the switching point or [Lock] flashes (release security lock
è
Chapter 5.7).
è
The sensor module switches to RUN mode.