SOPA-...
Festo – SOPA-... – 2017-09b English
25
5.3
Symbols for representing the menu structure
Symbol
Meaning
Automatic return to the basic status (RUN mode) when the monitoring time has
expired (here 80 seconds).
In order to return manually to the basic status (RUN mode), press the EDIT
button for 3 seconds.
Establish distance (for teaching the value TP).
Symbol on the display flashes (here Out A).
Security code active (lock – blocked against unauthorised programming).
Security code inactive.
Press pushbutton (A pushbutton here). Advance/switch to the menu.
/
Press the A pushbutton or B pushbutton. The SOPA then switches to the setting
indicated by the arrow.
+
C pushbutton: Press A pushbutton and B pushbutton simultaneously
(= C pushbutton).
+
Press pushbutton (here A pushbutton) and the EDIT button simultaneously.
/
Press the A pushbutton or B pushbutton. Set the value.
Press the Edit button.
Branch in the menu.
The setting last selected in the EDIT mode is indicated in the SHOW mode.
Display of current errors.
Delete minimum/maximum value.
Tab. 14
Symbols for representing the menu structure
5.4
RUN mode
In the basic status, the product is in RUN mode. The current distance-correlated values are displayed.
The basic status can be reached from other modes by:
–
pressing Edit button for 3 seconds or
–
expiration of a monitoring time, timeout.
The following are displayed in the RUN mode (depending on the setting of the switching output at
Pin2):
–
the numerical distance-correlated value or the values for supply pressure (in bar) and
–
a graphical display (bar graph) of the distance-correlated values in relation to the respective
switching points for binary signals Out A and/or Out B and
–
the signal statuses of the switching outputs Out A, Out B, Out C (set, not set).
A flashing value indicates that the measuring range has been exceeded.