The following are displayed in the INFO mode:
–
the input values In A, In B (distance) and In C (supply pressure).
The following are displayed in the SHOW mode:
–
the setting values for the switching signals (switching point, hysteresis, switching characteristic)
and
–
the extreme values of the input values (minimum distance, maximum distance) or
–
in the event of an error: display of the error number.
The following pushbutton allocations are applicable here:
–
A pushbutton: input values In A and the settings for the binary signal Out A.
–
B pushbutton: input values In B and the settings for the binary signal Out B.
–
A push B pushbutton (C pushbutton): input values In C and the settings for the binary signal
Out C.
Note
The supply pressure display is temporally limited to 80 seconds. After this time has
lapsed the numerical distance-correlated value is displayed again.
Calling the INFO mode and SHOW mode:
Requirement: SOPA is in RUN mode.
1. Press the A, B or C pushbutton.
è
SOPA displays the respective input value (or an error number).
2. Press the A, B or C pushbutton again.
è
SOPA displays the settings for the respective switching output one after the other.
Note
At the end of the SHOW mode, the respective minimum and maximum values are
displayed. If no other pushbuttons are pressed, this remains permanently on display
(notimeout).
The display of the minimum and maximum values can be reset by pressing the
Editbutton.
3. Press the A, B or C pushbutton again.
è
SOPA switches to RUN mode.