Festo SOPA-C series Operating Instructions Manual Download Page 24

SOPA-...

24

Festo – SOPA-... – 2017-09b English

5.2

Bar graph on the display

Display

Meaning

Segment at the bottom left and 

[A] flash

INFO mode active.

7-segment display shows the input value In A.

Segment at the bottom left and 

[A] illuminate, 

[min] or [max] flash.

SHOW mode active.

7-segment display shows the minimum or

maximum value In A.

Segment at the bottom right and 

[B] flash

INFO mode active.

7-segment display shows the input value In B.

Segment at the bottom right and 

[B] illuminate, 

[min] or [max] flash.

SHOW mode active.

7-segment display shows the minimum or

maximum value In B.

Both of the bottom segments and

[C] flash.

INFO mode active.

7-segment display shows the input value In C.

Segment at the bottom left and

right and [C] illuminate, 

[min] or [max] flash.

SHOW mode active.

7-segment display shows the minimum or

maximum value In C.

Marked segments illuminate and

[Option] flashes:

EDIT mode active.

Special menu opens.

7-segment display shows the set option.

Marked segments illuminate and

[Lock] flashes:

EDIT mode active.

Special menu opens.

7-segment display shows the security code.

Tab. 13

Special bar graphs on the display

Summary of Contents for SOPA-C series

Page 1: ...en Operating instructions 8078142 2017 09b 8068125 Air gap sensor SOPA...

Page 2: ...injuries Caution Hazards that can cause minor injuries Other symbols Note Material damage or loss of function Recommendations tips references to other documentation Essential or useful accessories Inf...

Page 3: ...parameter options 14 2 3 4 Switching off the display 14 2 3 5 Security code 14 2 3 6 Min max values 14 3 Requirements for product use 15 4 Installation 18 4 1 Mechanical system 18 4 2 Pneumatic syste...

Page 4: ...ion 33 6 1 Resetting the sensor module to its factory settings 33 6 2 Using the differential pressure regulator 34 7 Maintenance and care 34 8 Disassembly 35 9 Fault clearance 36 10 Accessories 37 11...

Page 5: ...8 6 9 aJ 1 Control module optional 2 Sensor module max 4 modules permitted in combination with control module 3 Plug for electrical connection 4 Display 5 Fastening slides 6 Threaded sleeve M4 7 Blan...

Page 6: ...EDIT button 5 B pushbutton 6 A pushbutton 7 Pneumatic connection for measuring nozzle output 8 Supply port for operating pressure 9 Vent screw width across flats 14 aJ Supply port for supply pressure...

Page 7: ...th electrically activatable manual override Sensing range R1 20 200 m Type of mounting H H rail mounting through hole W Additional wall mounting Pneumatic connection Q6 Push in connector 6 mm Electric...

Page 8: ...lay timeout di ON Security code lock OFF OutA Switching point SP 100 Hysteresis Hy 5 Switching characteristic NO normally open contact OutB Switching point SP 150 Hysteresis Hy 5 Switching characteris...

Page 9: ...ually and in combination with the control module 1 2 3 4 5 6 7 8 9 aJ 1 3 2 way valve instrument air 2 Pressure regulator 3 3 2 way valve exhaust air 4 Supply pressure 5 Sensor modules pneumatically l...

Page 10: ...nal statuses for binary signals Out A Out B Out C INFO mode Display of input variables in the display Switching of the display by pressing the A and or B pushbutton SHOW mode Display of current settin...

Page 11: ...le to set two independent binary signals for distance monitoring over the entire measuring range The binary signal Out C for monitoring the supply pressure always acts as an enable signal for the bina...

Page 12: ...erves to suppress switching signals in the event of fluctuations around the switching point The reset points function as long as the value is within the hysteresis range Upper reset point switching po...

Page 13: ...h sets of bars are only active if the switching output at Pin 2 is assigned to the binary signal Out B The bars run synchronously if Out A and Out B have the same switching point If different switchin...

Page 14: ...ction with deactivated exhaust air 2 Spurious pulse suppression with use of the function exhaust air on off and with instrument air switched off Tab 6 Options for spurious pulse suppression 2 3 4 Swit...

Page 15: ...into consideration Comply with the regulations of the workers compensation trade association the German Technical Control Board T V of the VDE or relevant national regulations Remove all transport pac...

Page 16: ...the event of gap distance queries of 30 m it may be necessary to reset the outlet openings of the nozzles by 30 60 m after the bearing surface in order to permit air discharge The bearing surface in w...

Page 17: ...hall be used with a suitable isolating source such that the maximum open circuit voltage potential available to the product is not more than 30 V DC and the current is limited to a value not exceeding...

Page 18: ...blanking plug 1 on the last sensor module max 4 so it is hand tight spanner size AF 3 mm Make sure the seal is seated properly Fig 9 Mounting the sensor module Attaching the sensor module Caution Mat...

Page 19: ...the mounting tabs engage in place Fig 12 Wall mounting Attaching the sensor module without a control module Use a suitable pressure regulator to guarantee the required supply pressure for all pneumati...

Page 20: ...t the supply port for the operating pressure to the compressed air source For operation without a control module Connect the supply port for the supply pressure to the precision pressure regulator 4 E...

Page 21: ...ines are always shorter than 10 m The max tightening torque of the plugs is max 0 3 Nm PIN allocation and control module circuit diagrams Pin Allocation Core colours1 Plug connector 1 Operating voltag...

Page 22: ...diagrams Pin Allocation Core colours1 Plug connector 1 Operating voltage 24 V DC Brown BN 5 pin M12 5 2 3 4 1 2 Switching output for Out B or Out C factory setting White WH 3 Operating voltage 0 V Bl...

Page 23: ...tive Option Options for spurious pulse suppression Off 1 2 LOCK Security code active block to prevent unauthorised parameterisation Special menu SPEC is active P2 Allocation of the switching output fo...

Page 24: ...ght and B illuminate min or max flash SHOW mode active 7 segment display shows the minimum or maximum value In B Both of the bottom segments and C flash INFO mode active 7 segment display shows the in...

Page 25: ...pushbutton or B pushbutton Set the value Press the Edit button Branch in the menu The setting last selected in the EDIT mode is indicated in the SHOW mode Display of current errors Delete minimum maxi...

Page 26: ...cal distance correlated value is displayed again Calling RUN mode 1 Pressurise the SOPA with the required operating pressure and or supply pressure Technical Data Chapter 11 2 Switch on the operating...

Page 27: ...shbutton C pushbutton input values In C and the settings for the binary signal Out C Note The supply pressure display is temporally limited to 80 seconds After this time has lapsed the numerical dista...

Page 28: ...mode the settings for the binary signals Out A Out B Out C and the special menu SPEC Warning Manipulation of signal statuses may cause serious personal injury depending on the functioning of the machi...

Page 29: ...is active and Out A flashes 3 Press the A B pushbutton if you want to switch to a different setting menu Out B Out C SPEC 4 Press the Edit button to confirm the selection SP flashes 5 Set the switchi...

Page 30: ...eleased Press the A B pushbuttons until the chosen security code is set Press the Edit button The EDIT mode is active and Out A flashes 3 Press the A B pushbuttons until Out C flashes 4 Press the Edit...

Page 31: ...ed binary signal by using the A B pushbuttons c Out C supply pressure monitoring at Pin 2 b Out B additional switching point for distance monitoring at Pin 2 8 Press the Edit button to confirm the sel...

Page 32: ...push button is the same The procedure is described below based on the binary signal Out A 1 Set the desired sensing distance between the object and measuring nozzle 2 First press the A pushbutton and...

Page 33: ...nsor module to its factory settings Note By resetting to factory settings the current settings are lost If required make a note of these settings before resetting Parameters Factory setting Out A Swit...

Page 34: ...the differential pressure regulator clockwise towards LOW until no air flows from the differential pressure regulator 5 Turn the adjusting screw on the differential pressure regulator counter clockwis...

Page 35: ...off the compressed air 3 Disconnect the connections for the control module and the sensor modules 4 Disassemble the device Fig 18 Wall mounting H rail mounting Plate mounting 1 2 1 2 1 Lift the devic...

Page 36: ...2 bar Observe the pressure range Chapter 11 Overpressure above permitted overload pressure device damaged Replace sensor module Outputs do not switch in accordance with the settings Short circuit or...

Page 37: ...le error messages of the sensor module 10 Accessories Designation Type Connecting cable Straight socket Angled socket NEBU M12G5 K NEBU M12W5 K Differential pressure regulator LRLL 1 8 QS 6 Adapter pl...

Page 38: ...or N O contact adjustable Repetition accuracy of switching point Sensing range 30 m 150 m Sensing range 20 m 200 m 2 5 5 Temperature coefficient of switching point 10 K Typically 2 Switch on time See...

Page 39: ...pply pressure bar 0 5 1 9 Setting range Threshold value Out C supply pressure MPa 0 05 0 19 Setting range Hysteresis Out A Out B distance 3 20 dimensionless Hysteresis Out C supply pressure mbar 204 2...

Page 40: ...5 m 2 m 3 m 5 m 8 m Fig 19 Typical response time t as a function of distance x after switching on the instrument air measuring nozzle 2 mm x m t ms Tube length in m 0 5 m 2 m 3 m 5 m 8 m Fig 20 Typic...

Page 41: ...ring nozzle 2 mm Repetition accuracy of the switching point Sensing range standard Extended sensing range only possible for type SOPA M1under 20 m in combination with recessed measuring nozzles over 2...

Page 42: ...late hole patterns SXE3 W X Distance dimension dependent on the number of sensor modules used Tab 20 Fig 23 Adapter plate hole patterns SXE3 W Number of sensor modules 1 2 3 4 Dimension X mm 1 83 5 10...

Page 43: ...s the Edit button The EDIT mode is active Out A flashes or Lock flashes if there is an active security lock release security lock Chapter 5 6 2 2 Press the Edit button again to confirm the selection S...

Page 44: ...zation is prohibited Offenders will be liable for damages All rights re served in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Ruiter Stra e 82 73734 E...

Reviews: