SOPA-...
Festo – SOPA-... – 2017-09b English
37
Indication on display
Error
Remedy
Er1
Sensor module defective
Replace sensor module.
Er17
1)
Undervoltage in supply voltage
Observe the voltage range.
(
è
Chapter 11).
Er42
Supply pressure (In C) outside the
measuring range (>2 bar, > 200 kPa);
no signal evaluation possible
Observe the measuring range
(
è
Chapter 11).
SUP.P
Supply pressure switched off or not
within the monitoring window
Observe pressure range
(feed pressure/supply pressure
è
Chapter 11).
1)
Display flashes. The lowest current error number is shown. The outputs are reset automatically.
Tab. 17
Possible error messages of the sensor module
10
Accessories
Designation
Type
Connecting cable
–
Straight socket
–
Angled socket
NEBU-M12G5-K-...
NEBU-M12W5-K-...
Differential pressure regulator
LRLL-1/8-QS-6
Adapter plate for wall mounting
1)
SXE3-...-W...
Blanking plug
B-M7
Push-in fitting
QSM-M7-6-I
1)
Included in the scope of delivery of SOPA-...-W-...
Tab. 18
SOPA accessories
11
Technical data
Technical data
SOPA-C
SOPA-M
General information
Certification
RCM Mark, c UL us – Recognized (OL)
CE mark (Declaration of Conformity
è
www.festo.com/sp)
According to EU EMC Directive
Note on materials
RoHS-compliant
Input signal/measuring element
Measured variable
Distance
Measuring principle
Pneumatic system
Sensing range
[μm]
20...200
Operating pressure
[bar]
4...7
Operating pressure
[MPa]
0.4…0.7
Supply pressure
[bar]
0.8...1.6