SOPA-...
Festo – SOPA-... – 2017-09b English
31
5.6.3
Setting special menu [SPEC]
1. Press the Edit button.
è
The EDIT mode is active and [Out A] flashes or, if there is an active security lock, [Lock] flashes.
2. If there is an active security lock, it must be released:
Press the A/B pushbuttons until the chosen security code is set.
Press the Edit button.
è
The EDIT mode is active and [Out A] flashes.
3. Press the A/B pushbuttons until [SPEC] flashes.
4. Press the Edit button to confirm the selection.
è
[Option] flashes. The signal processing option can now be set
Setting the signal processing option:
5. Select the desired setting (OFF, 1 or 2) using the A/B pushbuttons.
6. Press the Edit button to confirm the selection.
è
[P2-] flashes. The allocation of the switching output at Pin 2 can now be set.
Setting the allocation of the switching output at Pin 2:
7. Set the desired binary signal by using the A/B pushbuttons.
–
c = Out C = supply pressure monitoring at Pin 2,
–
b = Out B = additional switching point for distance monitoring at Pin 2.
8. Press the Edit button to confirm the selection.
è
[di.] flashes. The mode for deactivating the numerical display can be set.
Setting the mode for deactivating the numerical display:
9. Select the mode using the A/B pushbuttons.
–
on = numerical display is always on,
–
off = numerical display is always off,
–
1…90 = duration for which the display remains active after the last pushbutton is pressed
(inmin).
The numerical display is deactivated after this time expires.
[----] appears on the display.
10.Press the Edit button to confirm the selection.
è
[Lock] flashes. The security code can be set.
Setting the security code
Note
If you forget the security code, the SOPA must be reset to its factory settings (
è
Chapter 6).
11.Use the A/B pushbuttons to select between an inactive security code (OFF) or a maximum 4-digit
security code.
12.Press the Edit button to confirm the selection.
è
SOPA switches to RUN mode.