SOPA-...
Festo – SOPA-... – 2017-09b English
39
Technical data
SOPA-M
SOPA-C
Mechanical system
Installation position
Any
1)
Nominal diameter of measuring
nozzle
[mm]
2
Specified measuring nozzle
diameter
[mm]
1.5/2/2.5
Pneumatic connection
QS-6
2)
Specified tube length
[m]
0.5…8
Product weight
[g]
450
60
Information on housing materials
Reinforced PA/
anodised aluminium
PA reinforced
Keypad material information
PET
TPU
Inspection window material
information
PC
Sealing ring material information
Nitrile rubber
Adapter plate material information
Chromated steel
3)
Display/operation
Setting range
Threshold value Out A/Out B (distance)
20…300 (dimensionless)
Setting range
Threshold value Out C
(supplypressure)
[bar]
0.5 … 1.9
Setting range
Threshold value Out C
(supplypressure)
[MPa]
0.05 … 0.19
Setting range
Hysteresis Out A/Out B (distance)
3…20 (dimensionless)
Hysteresis Out C (supply pressure)
[mbar]
20
4) (2 kPa)
Immissions/emissions
Storage temperature
[°C]
–20…+80
Degree of protection
IP65 (according to EN 60529)
Internal air consumption
[SLPM]
4 ... 5
Instrument air consumption (sense)
[SLPM]
15
Blow out air consumption (clean)
[SLPM]
35
Protection class according to DIN VDE 0106-1
III
Shock resistance
according to DIN/IEC 68/EN 60068 Part 2-27
30 g acceleration with 11 ms duration (half-sine)
Vibration resistance
according to DIN/IEC 68/EN 60068, Part 2-6
0.35 mm travel at 10 … 60 Hz,
5 g acceleration at 60 … 150 Hz
1)
No condensed water should be able to accumulate in the sensor module
2)
Plug-ing connector for outer diameter of tubing 6 mm
3)
When selecting feature …-W-..
4)
Not adjustable
Tab. 19