![Festo MTR-DCI Manual Download Page 90](http://html1.mh-extra.com/html/festo/mtr-dci/mtr-dci_manual_2283488090.webp)
}
Settings
Homing parameter
Homing method
Velocity v_
sw
Velocity v_
s0
Save
5. Commissioning
5−12
Festo P.BE−MTR−DCI−IO−EN en 0606b
Set parameters
Depending on the set referencing method, the reference point
is defined by means of a reference switch or fixed stop. If
reference travel to a mechanical end position is not possible
in the application, an external sensor (reference switch) can
be used as reference signal (see also chapter 1.1.2).
Reference travel parameters
(factory setting)
32
42
52
62
Homing method
Reference switch, negative (near motor)
Velocitys v_sw, v_s0
%
1)
inc/s
~41 %
27000
~22 %
22400
~17%
16800
~15%
16800
Rated speed of the motor
rot/s
inc/s
55
66000
50
100000
50
100000
56,7
113400
1)
% of the rated speed of the motor; max. 50 %
·
Set the following reference travel parameters one after
the other:
the referencing method [Homing method]
the search speed for ascertaining the reference point
[Velocity v_sw]
the positioning speed to the axis zero point
[Velocity v_s0].
·
Accept each setting with OK <Enter>. The setting will then
become effective in the drive.
·
Save the parameter settings with the menu command
[Save]. Only then will the settings be retained even if the
power supply is switched off or if there is a power failure.
·
Finally, carry out reference travel, otherwise the previous
reference system of the MTR−DCI will remain unmodified.
Summary of Contents for MTR-DCI
Page 1: ...Manual Type MTR DCI IO Manual 539 616 en 0606b 700 619 Motor unit MTR DCI...
Page 4: ...Contents and general instructions II Festo P BE MTR DCI IO EN en 0606b...
Page 8: ...Contents and general instructions VI Festo P BE MTR DCI IO EN en 0606b...
Page 19: ...System summary 1 1 Festo P BE MTR DCI IO EN en 0606b Chapter 1...
Page 36: ...1 System summary 1 18 Festo P BE MTR DCI IO EN en 0606b...
Page 37: ...Fitting 2 1 Festo P BE MTR DCI IO EN en 0606b Chapter 2...
Page 45: ...Installation 3 1 Festo P BE MTR DCI IO EN en 0606b Chapter 3...
Page 59: ...Control panel MTR DCI H2IO 4 1 Festo P BE MTR DCI IO EN en 0606b Chapter 4...
Page 79: ...Commissioning 5 1 Festo P BE MTR DCI IO EN en 0606b Chapter 5...
Page 112: ...5 Commissioning 5 34 Festo P BE MTR DCI IO EN en 0606b...
Page 113: ...Operating maintenance and diagnosis 6 1 Festo P BE MTR DCI IO EN en 0606b Chapter 6...
Page 124: ...6 Operating maintenance and diagnosis 6 12 Festo P BE MTR DCI IO EN en 0606b...
Page 125: ...Technical appendix A 1 Festo P BE MTR DCI IO EN en 0606b Appendix A...
Page 137: ...Supplementary information B 1 Festo P BE MTR DCI IO EN en 0606b Appendix B...
Page 178: ...Index C 1 Festo P BE MTR DCI IO EN en 0606b Appendix C...
Page 179: ...C Index C 2 Festo P BE MTR DCI IO EN en 0606b Contents C Index C 1...