Abbreviation/term
Significance
I/O diagnostics
interface
Diagnostic interface at I/O level, which enables access to the internal data
of the bus node and the connected devices or modules
IPC
Industrial PC
I-port
I-port is a Festo-specific interface for transmitting communication data
(process data, sensor signals, pilot signals) and supply voltages. The
I-port communication protocol is based on the IO link protocol. The
electrical and mechanical link between bus nodes and I-port device is
standardised.
Load voltage
Comprises the voltage supply for connected devices and outputs,
e.g. I-port devices, electrical analogue or digital outputs, solenoid coils of
valves etc. (load voltage supply
see also “Operating voltage”: Voltage
supply for electronics and sensors)
O
Output
Object Directory
Makes all important fieldbus/network participant parameters accessible
in a standardised manner
ODVA
Open Device Vendor Association, DeviceNet umbrella organisation
Operating voltage
Also referred to as signal voltage; comprises the voltage supply for the
electronics/sensors (power supply
see also “Load voltage”: voltage
supply for outputs)
PDO
Process Data Objects facilitate the fast transmission of process data via
Multicast connection and are transmitted by simple DeviceNet messages
without protocol overhead; PDOs can be transmitted event-controlled,
synchronised with a system cycle or on request; a distinction is drawn
between
“TPDOs” and
“RPDOs”
PELV (Protective
Extra-Low Voltage)
Protective Extra-Low Voltage
Tab. A/7:
System-specific terms and abbreviations (General overview – Part 2)
Summary of Contents for CTEU-DN
Page 2: ......
Page 15: ...Introduction 1 1 Festo P BE CTEU DN OP MAINT EN en 1206NH Chapter 1 Introduction...
Page 22: ...1 Introduction 1 8 Festo P BE CTEU DN OP MAINT EN en 1206NH...
Page 44: ...2 Installation and interfaces 2 22 Festo P BE CTEU DN OP MAINT EN en 1206NH...
Page 57: ...Commissioning 4 1 Festo P BE CTEU DN OP MAINT EN en 1206NH Chapter 4 Commissioning...
Page 76: ...4 Commissioning 4 20 Festo P BE CTEU DN OP MAINT EN en 1206NH...
Page 77: ...Diagnostics 5 1 Festo P BE CTEU DN OP MAINT EN en 1206NH Chapter 5 Diagnostics...
Page 90: ...5 Diagnostics 5 14 Festo P BE CTEU DN OP MAINT EN en 1206NH...
Page 91: ...Error handling 6 1 Festo P BE CTEU DN OP MAINT EN en 1206NH Chapter 6 Error handling...
Page 98: ...6 Error handling 6 8 Festo P BE CTEU DN OP MAINT EN en 1206NH...
Page 99: ...Technical appendix A 1 Festo P BE CTEU DN OP MAINT EN en 1206NH Appendix A Technical appendix...
Page 124: ...A Technical appendix A 26 Festo P BE CTEU DN OP MAINT EN en 1206NH...
Page 125: ...Index B 1 Festo P BE CTEU DN OP MAINT EN en 1206NH Appendix B Index...
Page 126: ...B Index B 2 Festo P BE CTEU DN OP MAINT EN en 1206NH Contents B Index B 1...
Page 130: ...B Index B 6 Festo P BE CTEU DN OP MAINT EN en 1206NH...