PLEASE NOTE
In the case of CPV valve terminals with two pressure
zones and auxiliary pilot air taken internally on the
right-hand side, the pressure on the right-hand side
must be between 3 bar and 8 bar.
PLEASE NOTE
In the case of CPV valve terminals with ducted sup-
ply air, connections 11 and 12/14 must be sealed
with blind plugs.
Vacuum/low pressure operation
The CPV valve terminal can be operated with vacuum
or low pressure (< 3 bar), providing regulated auxiliary
pilot air is supplied separately A summary of the end
plates required can be found in chapter 5 under "Con-
version from internal to external auxiliary pilot air").
3. Installation
3-10
CPV... 9811d