Fitting variant: rear
Fitting variant: front
1
2
3
4
M4 screws (CPV10/14) or M5 screws
(CPV18) for wall fitting
Fixing bolts (only CPV10/14)
Self-cutting screws for fastening the
profiles to the CPV valve terminal
Additional self-cutting screw for
CPV14/18 valve terminals
1
2
M5.5 bore for wall fastening
Self-cutting screws for fastening the
profiles to the CPV valve terminal
Fig. 2/2: Fitting the CPV valve terminal onto a wall
•
Make sure that there is enough room to connect the
power cables and the pneumatic tubing. In the case
of front fitting, a suitable spacer or cutout section
must be provided to permit access to the electrical
connections (see Fig. 2/3).
PLEASE NOTE
The boring dimensions for rear fitting of the CPV
valve terminal (Fig. 2/3) do not apply to the
CPV10/14 valve terminals with direct connection for
Interbus Loop (type CPV..-GE-IBL-..) or for AS-i con-
nection with inputs/outputs (type CPV..-GE-ASI..E/..A).
2
1
3
4
1
1
2
2
2. Fitting
2-6
CPV... 9811d
Summary of Contents for CPV -VI Series
Page 1: ...Compact Performance CPV valve terminal Pneumatics Typ CPV VI...
Page 2: ......
Page 4: ...Part no 165 200 Title MANUAL Designation P BE CPV GB II CPV 9811d...
Page 15: ...Chapter 1 System overview 1 System overview CPV 9811d 1 1...
Page 31: ...Chapter 2 Fitting 2 Fitting CPV 9811d 2 1...
Page 53: ...Chapter 3 Installation 3 Installation CPV 9811d 3 1...
Page 69: ...Chapter 4 Commissioning 4 Commissioning CPV 9811d 4 1...
Page 83: ...Chapter 5 Maintenance and conversion 5 Maintenance and conversion CPV 9811d 5 1...
Page 106: ...5 Maintenance and conversion 5 24 CPV 9811d...
Page 107: ...Appendix A Technical appendix A Technical appendix CPV 9811d A 1...