3.2.2 Connecting the supply and work tubing
Fit the screw connectors or silencers as shown in the
table below. Then connect the tubing.
With pneumatic multiple connector plate
Without pneumatic multiple connector plate
Connection
code
ISO 5599
Tubing
Connection size ISO 228,
Specifications in brackets
for extended pneum.
multiple connector plate
Connection
CPV10
CPC14
CPV18
1 or 11
Compressed air/
vacuum
G 1/8
G 1/4
G 3/8
Screw connector in end
plates or pneumatic
multiple connector plate
2 or 4
Work air/vacuum
M7
G 1/8
G 1/4
Screw connector
3/5
Exhaust right/
left-hand end plate
Pneum. multiple
connector plate
G 3/8
G 1/4
G1/2
G3/8
G 1/2
G 1/2
Screw connector
- for ducted exhaust air
- for silencers
12/14
or
82/84
Auxiliary pilot air/
exhaust right/
left-hand end plate
Pneum. multiple
connector plate
M5
M7 (M5)
G 1/8
G 1/8
G 1/4
G 1/4
Screw connector on
connection 82/84
- for ducted exhaust air
- for silencers
Fig. 3/3: Assigning the connections
3/5
3/5
11
4
2
2
4
11
1
82/84
82/84
12/14
1
1
12/14
11
3. Installation
3-8
CPV... 9811d
Summary of Contents for CPV -VI Series
Page 1: ...Compact Performance CPV valve terminal Pneumatics Typ CPV VI...
Page 2: ......
Page 4: ...Part no 165 200 Title MANUAL Designation P BE CPV GB II CPV 9811d...
Page 15: ...Chapter 1 System overview 1 System overview CPV 9811d 1 1...
Page 31: ...Chapter 2 Fitting 2 Fitting CPV 9811d 2 1...
Page 53: ...Chapter 3 Installation 3 Installation CPV 9811d 3 1...
Page 69: ...Chapter 4 Commissioning 4 Commissioning CPV 9811d 4 1...
Page 83: ...Chapter 5 Maintenance and conversion 5 Maintenance and conversion CPV 9811d 5 1...
Page 106: ...5 Maintenance and conversion 5 24 CPV 9811d...
Page 107: ...Appendix A Technical appendix A Technical appendix CPV 9811d A 1...