5.2 Conversion from automatic reset manual override to
locking manual override
By removing a safety clip, you can convert your CPV
valve terminal from automatic reset manual override to
locking manual override. Proceed as follows:
If you do not wish to use the safety clip again:
•
Use a screwdriver to press in the centre of the safety
clip, as shown in
1
. The safety clip will then bend
and can be removed from the fastening.
If you wish to use the safety clip again:
•
Use a thin object (e.g. a spatula) to lift the safety clip
out of the fastening as shown in
2
.
1
2
Remove the safety clip by pressing it out
Remove the safety clip by lifting it out (clip can be used again)
Fig. 5/5: Safety clip of the manual override
1
2
5. Maintenance and conversion
CPV... 9811d
5-13