No.
Description
Possible reason for error
F.1B3
TST UTA 1 Bluetooth
communication error
The Bluetooth communication of the TST UTA 1 is disturbed
F.1B4
TST UTA 1 is incompatible with
the control box
The TST UTA 1 is not compatible with used controller version --> Update the control box software
F.1B6
Pairing of the TST UTA 1 not
possible
The pairing with the customer coding of the controller for the TST UTA 1 has failed --> replace UTA 1 with a not yet
paired version.
F.1B8
TST UTA 1 Customer coding
TST UTA 1 and the door controller are not compatible
F.1BE
TST UTA 1 Software Update
Failed
An error occurred during the update. --> Start update again.
F.201
Internal emergency Stop
"mushroom button" triggered or
watchdog (monitoring)
• Stop chain was interrupted starting at input „internal--Stop“ without parametrizing mode having been selected
• Internal parameter or EEPROM checks defective, pressing the STOP button provides additional information about
the cause.
F.211
External emergency stop 1
triggered
• Emergency stop chain was interrupted from emergency stop input 1
F.212
External emergency stop 2
triggered
• Emergency stop chain was interrupted from emergency stop input 2
F.320
Obstacle during opening
• During opening an obstacle has recognized
F.325
Obstacle during closing
• During closing an obstacle has recognized
F.360
Short circuit detected on edge
input
• Short circuit detected on edges with normally closed contact
• The light beam of the optical edge is interrupted
• Jumper for 1K2 / 8K2 is wrong set
F.361
Number of trips of the Safety
input D, normally this is the
integrated safety edge
evaluation, has reached set
limit (configurable in P.46E)
• Parametrized, maximum number of trips of the safety input D during a door cycle was exceeded → To reset close
the door in jog mode
• Check the set number of reversing trips in P.46E
F.362
Redundancy error with short
circuit
• One of the processing channels for short circuit detection does not react identically with the second channel
→ Controller board defective, if no other error message F.3xx is present
• Dynamic optical system connected but not set in parameter P.460
F.363
Interruption on edge input
• Connection cable defective or not connected
• Termination resistor incorrect or missing
• Jumper 1K2 / 8K2 incorrectly set
F.364
Safety edge testing failed
• Safety edge was not activated as expected when requesting a test.
• The time between request for testing and actual testing not in agreement
• The pre-limit switch is set incorrectly
F.366
Too high a pulse frequency for
optical safety edge
• Faulty optical safety edge
• Defective input for internal safety edge