FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 88 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
No.
Description
Possible reason for error
F.962
Converter parameters not
plausible
• New EPROM version
• Controller not yet initialized
F.964
Program version / manufacturer
code
• New EPROM version
• Controller not yet initialized
F.965
Faulty door cycle counter with
active emergency opening
• The door cycle counter does not count or is faulty. Because of this no emergency opening testing can be done.
F.966
Hardware unknown
• A wrong software was programmed to the controller
• The programmed software does not recognize the hardware version
• The controller hardware is defective
F.967
Incompatible TST LGB software
version
TST LGB with software version V3.21 or earlier in combination with DES-A connected and activated.
F.968
Programming error with Real
time clock
• The clock is not programmed plausible
F.969
Internal real time clock error
• The clock has an error → make a reset
F.970
Plausibility parameter block
error
• New EPROM version
• Controller not yet initialized
• Some parameter is implausible