No.
Description
Possible reason for error
F.610
LGB Light line alignment
Light line alignment has not been done
F.611
Light curtain light line position
values not plausible
Position values stored by the light curtain do not match door movement
F.612
LGB RS485
RS485 communication error -> not enough valid position data
F.613
Internal RS-485
RS-485 communication error between Transmitter and Receiver
F.615
LGB internal transmitter
Internal error transmitter Indicates:
- RAM test fail
- ROM test fail
- Program run error
- Sync error
- Address module defective
- dark test fail
- DA converter defective
exchange hardware!
F.616
Internel error Light curtain
Receiver
Internal receiver error
• RAM test fail
• ROM test fail
• Program run error
• Sync error
• Addressing module defective
• Dark test fail
• D/A converter defective
• Watchdog not triggered or hangs
• Replace hardware!
F.617
Light curtain incompatibility
Transmitter and receiver are not compatible.
• modified Transmitter serial number
• incompatible Hardware version / revision level
• incompatible Software version
F.621
Light curtain test error
(transmitter)
test error for the internal transmitter system test
F.622
Light curtain test error
(receiver)
test error for the internal receiver system test
F.626
Light curtain test error (Out 1)
Test / wiring error of output 1
F.627
Light curtain test error (Out 2)
Test / wiring error of output 2
F.628
Light curtain LGB dark test
error