TST
Assembly instructions
FUZ2 -A/-B/-C/-CX/-G/-L
FEIG ELECTRONIC GmbH
Page 69 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
The display shows the messages in alternation: The door was
recognized in the CLOSE position and the light rays were
taught-in correctly.
!Korrekturfahrt!
xxx Start mit
I.515
!Korrekturfahrt!
I615 LL Abgl. ok
I.610
The subsequent OPENING and CLOSING of the door in
automatic mode adjusts the pre-limit switches and limit
switch tapes are taught-in automatically.
8. Start correction drive by pressing the
OPEN-key.
!Korrekturfahrt!
xxx Start mit
I.515
Door opens and is taught-in into the position.
Tor öffnet
I.555 Lernfahrt
I.555
Display in end position OPEN.
Offenh = xxs
I.515 Korr. Fahrt
I.515
The door will close automatically after the auto close time has
count down and moves up and down by itself until the
correction drive has finished.
The Display shows the following messages:
Tor schließt
I.515 Korr. Fahrt
I.515
Offenhalt = xxs
I.515 Korrekt. Fahrt
I.515
Display that correction was completed.
Offenh 1 = xxs
I.510 Korrek. OK
T.5
Offenh 1 = xxs
Automatik
T.5
Tor öffnet
I.515
`AUF`
Offenh 1 = xxs
T10
The door closes and remains in the end position CLOSE.
Tor schließt
2
UF`
The start up of the light curtain has been successfully
completed.
FEIG ELECTRONIC
xxxx Zyklen
_EU_
Usually the lower end position CLOSED has to be corrected afterwards. This can be defined using the
following parameters:
P.221: Correction value end position door CLOSE -> this parameter must be reset after every new teach-in
of all end positions (P.210=5).
P.275: Correction of increments after conclusion of the synchronization -> recommended as fine setting for
the end position BELOW. The value set here must NOT be re-set after the new teach-in of all end
positions.