DB:
Data of the data block to be written to the Transponder. The required block size is defined by
DB-SIZE. The number of the expected bytes are DB-N * DB-SIZE.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS =
0x95.
DB-ADR-E:
Block number were the error occurred.
Notes:
•
A write to 1 block uses a Write Single Block command to the Transponder. This will be man-
aged by the Reader internally.
•
If a Transponder does not support Write Multiple Blocks commands several Write Single
Block commands are used for this Transponder.
•
If an error occurred during a write command, the number of the block were the error oc-
curred will be send to host
•
A write command on I-Code UID and EPC Transponders can only be performed in the non-
addressed mode whereas the block-size (DB-SIZE) must be 1 Byte.
•
If an I-Code UID and EPC Transponder is already locked, the reader answers with status =
[0x03].