![background image](http://html1.mh-extra.com/html/feig-electronic/ibid-i-scan-id-isc-mr200/ibid-i-scan-id-isc-mr200_manual_3869664051.webp)
OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 51 of 144
H40801-5e-ID-B.doc
3.15.
CFG16: Persistence Reset
The parameters in CFG16 are used to configure the Reader reset timing of the persistence flags of the
Transponders. The timing for reset of the persistence flags is used by the Reader in Host Mode, Scan
Mode, Buffered Read Mode and Notification Mode.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
PER-RESET-TIME-ANT_1
0x00
0x00
0x00
Default
0x00
0x00
0x0028
0x00
0x00
0x00
40 x 5ms = 200ms
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
PER-RESET-TIME-ANT_1:
The timer value specifies a time which determine the reset of the Transponder persistence
flags by the Reader. The timer PER-RESET-TIME-ANT_1 starts after the Reader gets a re-
sponse at the antenna port. After this time has expired the Reader send a persistence reset
command to the Transponders at the antenna port.
Timer ticks = 5ms
Maximum timer value = 5ms x 65534[0xFFFE] = 5,46125 min.
The value 65535 [0xFFFF] indicates that no persistence reset is performed by the Reader