OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 38 of 144
H40801-5e-ID-B.doc
ONT:
Defines which Transponder will send to the host.
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ACOLL
0
1
ACOLL:
This bit activates the Anticollision Mode. In Anticollision Mode the Reader automati-
cally sets Transponder specific communication parameters.
b0:
disabled
In this case the Reader doesn’t processes any anticollision procedure with
the Transponders inside the antenna field.
b1:
enabled (default)
In this case the Reader processes the anticollision procedure with the
Transponders inside of the antenna field.
Note:
If 1 timeslot is set and the CRC on an I-Code EPC is wrong the serial number will be transferred
and the status is set to “[0x02] Data False”