![background image](http://html1.mh-extra.com/html/feig-electronic/ibid-i-scan-id-isc-mr200/ibid-i-scan-id-isc-mr200_manual_3869664114.webp)
OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 114 of 144
H40801-5e-ID-B.doc
7.1.5. Fujitsu (MB89R119)
IC manufacturer identifier: 0x08
Chip ID: 2h = 00000010b (Bit 47 - 40 of UID)
Memory organization: 64 x 4 Byte = 2kBit
Number of blocks
64 (user area: 0 – 57)
Block size
4 byte
WR-OPTION
0 or 1
Command
Code
Function
Mode
Comment
non-
addressed
addressed
select
0x01
Inventory
√
-
-
0x02
Stay Quiet
√
-
√
-
0x22
Lock Multiple Blocks
√
√
√
-
0x23
Read Multiple Blocks
√
√
√
-
Security Status is always
0x00
0x24
Write Multiple Blocks
*
√
√
√
-
0x25
Select
-
-
-
-
0x26
Reset to Ready
√
√
√
-
0x27
Write AFI
√
√
√
-
0x28
Lock AFI
√
√
√
-
0x29
Write DSFID
√
√
√
-
0x2A
Lock DSFID
√
√
√
-
0x2B
Get System Information
√
√
√
-
0x2C
Get Multiple Block Security
Status
-
-
-
-
*
The WR-OPTION will be set automatically by the FEIG Readers if the WR-OPTION parameter
is set to “00: automatically set”. Up to two blocks of data can be written for one request.