OBID i-scan
®
System-Manual
ID ISC.MR200
FEIG ELECTRONIC GmbH
Page 26 of 144
H40801-5e-ID-B.doc
3.3. CFG1: Interface
The parameters of the CFG1 configuration block contains the data communication settings.
Byte
0
1
2
3
4
5
6
Contents
COM-ADR
0x00
BAUD
1
TRANS-
FORM
1
0x00
0x00
TR-
RESPONSE-
TIME
Default
0x00
0x08
0x01
0x02
0x00
38400 Baud
e,8,1
Byte
7
8
9
10
11
12
13
Contents
TR-
RESPONSE-
TIME
0x00
0x00
0x00
SCAN-
INTERFACE
0x00
READER -
MODE
Default
0x58
0x00
0x00
3 sec.
COM-ADR:
Bus address of the Reader (0 .. 254) for communication via the asynchronous interface, es-
pecially for applications with the RS485 interface.
Notes:
•
Do not configure address 255!
•
Via the COM-Adr 255 in the send protocol, the Reader is able to be addressed at any
time. It answers then with the configured address.
1
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Reader
answers with STATUS = 0x11.