3.27. CFG49: Notification Channel (not used for ID ISC.MR200-A)
Byte
0
1
2
3
4
5
6
Contents
MODE
TIME-
TRIGGERED
-TIME
0x00
0x00
KEEP-ALIVE
KEEP-ALIVE-TIME
Default
0x00
0x01
0x00
0x00
0x00
0x02
0x58
continuously
1s
Off
600s = 10min
Byte
7
8
9
10
11
12
13
Contents
DEST-IP-ADDRESS
DEST-IP-PORT
HOLD-Time
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x01
MODE:
Defines the basic settings for the notification channel.
Bit:
7
6
5
4
3
2
1
0
Function
ACK
0
0
0
0
0
DATA-TRIGGER
DATA-TRIGGER:
b00:
continuously
b01:
time-triggered
The trigger definition is only for data records. In continuous and time-triggered mode
the data are notified always immediately. For detailed message conditions, see
1.4.
Notification Mode
. The message format is described in
10.3. [0x22] Read Buffer.
ACK:
Acknowledge Notification
b0:
Notification must not be acknowledged
b1:
Notification must be acknowledged with protocol [0x32] Clear Data Buffer
TIME-TRIGGERED-TIME:
Defines the cycle time in time-triggered mode.
max. time period
TIME-TRIGGERED-TIME
0...255 * 1s
KEEP-ALIVE:
Mode for keep alive notification.
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
0
EN