H40801-5e-ID-B.doc
3.11. CFG12: Read Mode - Filter
Byte
0
1
2
3
4
5
6
0x00
VALID-TIME
1
TR-ID
0x00
Default
0x0037
5,5sec.
0x01
0x00
0x00
0x01
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
VALID-TIME:
(0...65535 x 100 ms = 0 ms ... 6553,5 sec)
The period of time during which a Transponder can’t be read a 2
nd
time.
Note:
•
Changing of VALID-TIME only becomes effective after writing / saving configuration
block CFG12 to EEPROM and reset of the RF Controller with
5.4. [0x64] System Re-
set
in mode 0x00.
TR-ID:
(only for Buffered Read Mode and Notification Mode)
TR-ID sets the parameters for Transponder identification.
If several Transponders has the same content in the addressed data block, only one dataset
will be generated.
Byte:
2
3
4
5
Function
TR-ID-
SOURCE
TR-ID-DB-ADR
TR-ID-DB-N
TR-ID-SOURCE:
Sets the data source for Transponder identification.
b0
data block
b1
Serial Number
TR-ID-DB-ADR
Sets the address of the data block for Transponder identification. If ID-SOURCE se-
lects the Serial Number as data source, the ID-DB-ADR will be ignored.
TR-ID-DB-N
Sets the number of data blocks to be read for Transponder identification. If ID-
SOURCE selects the Serial Number as data source, the ID-DBN will be ignored.