SmartSiren Platinum Convergence Network
Federal Signal www.fedsig.com
Connecting the Convergence Network
22
Table 7 Descriptions of configurable activation options for 10 A relays
Configured
Activation
Description
Active High
The relay su12 Vdc during the “on” state.
Active Low
The relay supplies ground during the “on” state.
Open Off
The relay is open during the “off” state, a condition similar to an open
electromechanical relay.
Inverse Off
The NC relay alternates from its former polarity to the other each time it is
in the “off” state.
Figure 5 Configurable activation options for 10 A relays with active-low capability
ON
OFF
ON
OFF
ACTIVE HIGH
ACTIVE LOW
INVERSE OFF
OPEN OFF
−GND
+12 V
OUT
+12 V
OUT
+12 V
OUT
+12 V
OUT
−GND
−GND
−GND
OUT
−GND
OUT
OUT
OUT
+12 V
+12 V
290A6413
Figure 7 on page 24 shows the connectors for the 10 A relay cable assembly on
the back of the amplifier/relay module. The relays are fused on top of the module
with 10 A mini-blade fuses. Extend wiring with 18 AWG leads or thicker. Insulate
spliced leads with twist-on wire connectors. Fold and seal unused leads.