Maintenance - Annually (Every 2,000 hours of operation)
2018-02-20
4812325559EN
91
Annually (Every 2,000 hours of operation)
Clean the reservoir and replace the hydraulic oil
and filters
1.
Park the machine in a leveled ground and shut off the engine.
2.
Provide a container capable of draining the hydraulic circuit
reservoir.
3.
Remove the inspection cap, located on the upper part of the
reservoir, releasing its fixing bolts.
NOTE:
Remove eventual residues of the flange seal joint on the
inspection orifice.
4.
Open the drainage plug and drain all the reservoir content.
TAKE CARE OF THE ENVIRONMENT: All used
oil shall be collected and stored properly for
recycling. Do not discard oil on the soil,
sewerage system or any other location that
can harm the environment.
5.
Perform an internal cleaning of the reservoir using hot water
under pressure, with a proper detergent. Clean the reservoir
until the dirt is totally eliminated, than dry it with pressurized
air.
6.
Close the drainage plug and reinstall the inspection cap,
tightening the fixing bolts.
NOTE:
Replace the seal joint cap.
7.
Fill the reservoir with recommended hydraulic oil until the
correct level (refer to “Check the oil reservoir level”).
Use only hydraulic oil recommended by
DYNAPAC.
8.
Replace the hydraulic oil filter elements (refer to the item
“Replace hydraulic oil filters").
9.
Start the engine and operate the main functions of the
hydraulic circuit, such as brakes and the fan drive circuit.
10.
Check the oil level and fill it, if necessary.