Ambient temperature Oil viscosity
higher than 25 °C
(77 °F)
SAE 30
SAE 10W-30
SAE 15W-40
-10 °C to 25 °C (14 °F
to 77 °F)
SAE 10W-30
SAE 15W-40
below - 10 °C (14 °F) SAE 10W-30
8.3.1.3 Oil change intervals
If the oil change intervals are not reached over
a period of one year, the oil change should be
performed at least 1 x per year, irrespective of
the operating hours reached.
If the sulphur content in the fuel is higher than
0.5 %, the oil change intervals must be halved.
8.3.2 Fuel
8.3.2.1 Fuel quality
We recommend using a diesel fuel with a sul-
phur content of less than 0.1 %.
When using a diesel fuel with a high sulphur
content of 0.5 % to 1.0 % the oil change inter-
vals must be halved.
Fuels with a sulphur content of more than
1.0 % are not permitted.
In order to fulfil national emission regulations
one must strictly use the legally required fuels
(e.g. sulphur content).
For engines used in EPA areas, the use of
diesel fuels with ultra-low sulphur content is
mandatory (ASTM D975 Grade-No. 1-D S15
and 2-D S15).
Maintenance – Fuels and lubricants
BW 100 ADM-5
146
Summary of Contents for BOMAG BW 100 ADM-5
Page 9: ...1 Introduction Introduction BW 100 ADM 5 9 ...
Page 13: ...2 Technical data Technical data BW 100 ADM 5 13 ...
Page 18: ...Technical data Noise and vibration data BW 100 ADM 5 18 ...
Page 19: ...3 Concerning your safety Concerning your safety BW 100 ADM 5 19 ...
Page 65: ...4 Indicators and control elements Indicators and control elements BW 100 ADM 5 65 ...
Page 82: ...Indicators and control elements Outside of machine BW 100 ADM 5 82 ...
Page 83: ...5 Checks prior to start up Checks prior to start up BW 100 ADM 5 83 ...
Page 97: ...6 Operation Operation BW 100 ADM 5 97 ...
Page 128: ...Operation Emergency procedures BW 100 ADM 5 128 ...
Page 129: ...7 Loading transporting the machine Loading transporting the machine BW 100 ADM 5 129 ...
Page 139: ...8 Maintenance Maintenance BW 100 ADM 5 139 ...
Page 194: ...Maintenance As required BW 100 ADM 5 194 ...
Page 195: ...9 Setting up refitting Setting up refitting BW 100 ADM 5 195 ...
Page 200: ...Setting up refitting Edge cutter mounting and removing tools BW 100 ADM 5 200 ...
Page 201: ...10 Troubleshooting Troubleshooting BW 100 ADM 5 201 ...
Page 206: ...Fuse Amperage Designation F00 80 A Main fuse Troubleshooting Fuse assignment BW 100 ADM 5 206 ...
Page 212: ...Troubleshooting Trouble shooting ECONOMIZER BW 100 ADM 5 212 ...
Page 213: ...11 Disposal Disposal BW 100 ADM 5 213 ...
Page 215: ......
Page 216: ......