Connection to the CANopen network
Fig. 36: Connection to the CANopen network
Connection of the STO safety control
Fig. 37: Connection of the STO safety control
If the CAN wiring is not laid in a straight line it may be necessary to individually opti-
mise the amount and location of the terminating resistors. For instance in a star net-
work a central 60 Ohm terminating resistor may be more suitable. When the optimum
arrangement of terminating resistors is fitted, no accumulation of error frames should
be evident.
Node 1
C
AN Bus Line
Node n
GND
C
AN_H
C
AN_L
120
120
Safety Control
No
d
e 1
No
d
e n
STO IN 1
STO IN 2
STO OUT 2 Error
STO OUT 1 Status
STO 24 V IN