1st edition, 03-05-2018
7000.05063, 1st edition, 03-05-2018
7000.05063
Installation
45
STO inputs
DANGER
DANGER
!
The safety function of the Motion Controller is not ensured if connected incorrectly.
Observe the safety information in chap. 4.2.1, p. 28 and chap. 2.2.2, p. 10.
WARNING
WARNING
!
Unexpected startup of the drive or shutdown of the torque.
Because there is no redundancy when the circuit of the two STO inputs is bridged, there is a
risk of serious injury or death.
Bridged circuit (see Fig. 24) is only to be used for applications up to Performance Level c
(PL a, PL b, PL c).
For applications with Performance Level d or higher (PL d, PL e) that use redundant cir-
cuitry (see Fig. 25).
Fig. 24: Circuit diagram of bridged STO inputs 1 and 2
STO In
STO 1
STO 2
STO GND
PL a, PL b, PL c
Summary of Contents for MC 5004 P STO